OSHA Inspection: COATING EXCELLENCE INTERNATIONAL LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COATING EXCELLENCE INTERNATIONAL LLC in 975 BROADWAY ST., WRIGHTSTOWN, WI 54180 (NAICS 326111). OSHA activity number 342377751.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coating Excellence International LLC — free Get an email when a new federal OSHA severe-injury report for Coating Excellence International LLC is published. One employer, no account, unsubscribe in one click.
Site address
975 BROADWAY ST.
City
WRIGHTSTOWN
State
WI
ZIP
54180
Mailing
975 BROADWAY ST., WRIGHTSTOWN, WI 54180
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
449
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II D

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2017
Abate by
Oct 17, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:  a)  On or about May 31, 2017, the employer did not ensure to write down in the energy control procedures that it was a requirement for employees to test the machine to determine and verify that the Thiele Technologies, Inc., Machine #BCSP1(Serial #HS75OSHA103) machine was locked out.   b)  On or about May 31, 2017, the employer did not ensure to write down on the energy control procedures what were the energy sources that the employees were to test to determine that the Thiele Technologies, Inc., Machine #BCSP1(Serial #HS75OSHA103) was locked out properly.
Recent events (2)
  • — I (S) $12675
  • — Z (S) $12675

1910.147 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2017
Abate by
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.  a)  On or about May 31, 2017, the employer did not ensure that the machine was shut down when employees were cleaning the build-up of glue near a chain and sprocket on the polypropylene laminated bag on the Thiele Technologies, Inc., Machine #BCSP1(Serial #HS75OSHA103).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 19, 2017
Abate by
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself.  a)  On or about May 31, 2017, the employer did not ensure that the machine had fixed guarding when employees were cleaning the build-up of glue near a chain and sprocket by the glue head and pinch closed glue unit on the Thiele Technologies, Inc., Machine #BCSP1 (Serial #HS75OSHA103).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 19, 2017
Abate by
Oct 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above the floor or platform were not enclosed:  a)  On or about May 31, 2017, the employer did not ensure that the chain and sprocket by the air line and glue head to  that a guard was installed on prevent employees from contacting on the Thiel Technologies, Inc., Machine #BCSP1 (Serial #HS75OSHA103).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 6 instances 3 exposed
Issued
Sep 19, 2017
Abate by
Oct 17, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefore, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:  a)  On or about June 6, 2017,  the employer did not ensure that a guard was installed on the sewing head to prevent employees from contacting the two needles on the machine on the Thiel Technologies, Inc.,  BCSP1 machine (Serial #HS75OSHA103).   b) On or about June 5, 2017, the employer did not ensure that a guard was installed on the sewing head to prevent employees from contacting the two needles on the machine on the Thiel Technologies, Inc., BCS#3 machine (Serial #HS75OSHA101).  c)  On or about May 23, 2017, the employer did not ensure that a guard was installed on the sewing head to prevent employees from contacting the two needles on the machine on the Thiel Technologies, Inc., BCS#4 machine (Serial #HS75OSHA101).  d)  On or about June 6, 2017, the employer partially guarded the web forming area to prevent employees from contacting the in-going nip points behind the guard on the Thiel Technologies, Inc., BCSP1 machine (Serial #HS75OSHA103).   e)  On or about June 6, 2017, the employer partially guarded the web forming area to prevent employees from contacting the in-going nip points behind the guard in the machine on the Thiel Technologies, Inc., BCS#3 machine (Serial #HS75OSHA101).   f)  On or about June 6, 2017, the employer partially guarded the web forming area to prevent employees from contacting the in-going nip points behind the guard in the machine on the Thiel Technologies, Inc., BCS#4 machine (Serial #HS75OSHA101).
Recent events (2)
  • — I (S) $12675
  • — Z (S) $12675

1910.219 C04 I

Other-than-serious 7 instances 3 exposed
Issued
Sep 19, 2017
Penalty
Initial $8,465 · Current $3,000 Reduced
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves:    a) On or about June 6, 2017, the employer did not ensure that three of the shaft ends were projecting less than one-half of the diameter of the shaft on the Thiel Technologies, Inc., Machine #BCSP1 (Serial #HS75OSHA103).     b)  On or about June 6, 2017,  the employer did not ensure that three of the shaft ends were projecting less than one-half of the diameter of the shaft on the Thiel Technologies, Inc., Machine #BCS3, (Serial #HS75OSHA103).    c)  On or about June 6, 2017, the employer did not ensure that one of the shaft ends were projecting less than one-half of the diameter of the shaft on the Thiel Technologies, Inc., Machine #BCS4, (Serial #HS75OSHA101).
Recent events (2)
  • — I (O) $3000
  • — Z (S) $8465

View Coating Excellence International LLC's full OSHA safety record →