WELLINGTON, OH —
OSHA Inspection: MARKS CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARKS CONSTRUCTION, INC. in STATE ROUTE 58, WELLINGTON, OH 44090 (NAICS 238910). OSHA activity number 342381233.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARKS CONSTRUCTION, INC.
- Site address
- STATE ROUTE 58
- City
- WELLINGTON
- State
- OH
- ZIP
- 44090
- Mailing
- 5855 CENTER ROAD, VALLEY CITY, OH 44280
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Jul 5, 2017
- Penalty
- Initial $2,716 · Current $1,901 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On June 6, 2017, at a tractor supply store new construction site on route 58 south of Wellington Township there was an active trench excavation project. The trench was approximately 10 feet deep with steel shoring securing the sides (trench box). The trench box did not have a ladder or other safe means of access/egress for an employee working at the base of the trench from inside the shoring.
Recent events (2)
- — I (S) $1901.2
- — Z (S) $2716
1926.1053 B01
- Issued
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On June 6, 2017, there was a 10 foot portable ladder placed into a shoring box for an employee to climb out of the 10 foot deep excavation at an active trench project. The ladder did not extend three feet above the upper landing surface edge.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B05 I
- Issued
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: On June 6, 2017, there was a 10 foot portable ladder placed into a shoring box for an employee to climb out of the 10 foot deep excavation at an active trench project. The ladder was used at approximately 90 degrees vertically from the ground below and placed next to the braces of the shoring box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B06
- Issued
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(6): Ladders were used on surfaces which were not stable and level: On June 6, 2017, there was a 10 foot portable ladder placed into a shoring box for an employee to climb out of the 10 foot deep excavation at an active trench project. The base of the ladder was placed on an unleveled and unstable surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Jul 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On June 6, 2017, the employer provided a damaged and bent defective ladder for an employee to climb out of a shoring box that was protecting a 10 foot deep trench. One of the side rails for the top four rungs of the ladder were severely bent.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Marks Construction, INC.
View Marks Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342381233.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.