MILWAUKEE, WI —
OSHA Inspection: SUPERIOR MASONRY BUILDERS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPERIOR MASONRY BUILDERS, INC. in 1623 N. JACKSON, MILWAUKEE, WI 53202 (NAICS 238140). OSHA activity number 342420809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPERIOR MASONRY BUILDERS, INC.
- Site address
- 1623 N. JACKSON
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53202
- Mailing
- 12699 W. ARDEN PL., BUTLER, WI 53007
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 80
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01 I
- Issued
- Nov 20, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $7,986 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit was not installed so that the space between the platform and the unit was no more than 1 inch wide. (a) The employer did not ensure that each plank did not have more than 1 inch wide spacing between each unit.
Recent events (2)
- — I (S) $0
- — Z (S) $7986
1926.451 B04
- Issued
- Nov 20, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $7,985 · Current $7,985
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). (a) Each end of a platform was not cleated or restrained and did not extend over the centerline support by at least 6 inches as required.
Recent events (2)
- — I (S) $7985
- — Z (S) $7985
1926.451 B07
- Issued
- Nov 20, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $7,985 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap was not at least 12 inches (30 cm) and the platforms were not nailed together or otherwise restrained to prevent movement: (a) The employer did not ensure that the overlapping planks were at least 12 inches and that the platforms were nailed together or otherwise restrained to prevent movement where platforms were overlapped to create a long platform.
Recent events (2)
- — I (S) $0
- — Z (S) $7985
More inspections at Superior Masonry Builders, INC.
View Superior Masonry Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342420809.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.