Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR MASONRY BUILDERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUPERIOR MASONRY BUILDERS, INC. in 1623 N. JACKSON, MILWAUKEE, WI 53202 (NAICS 238140). OSHA activity number 342420809.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Masonry Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Superior Masonry Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1623 N. JACKSON
City
MILWAUKEE
State
WI
ZIP
53202
Mailing
12699 W. ARDEN PL., BUTLER, WI 53007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
80
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Nov 20, 2017
Abate by
Nov 27, 2017
Penalty
Initial $7,986 · Current $0 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit was not installed so that the space between the platform and the unit was no more than 1 inch wide.  (a) The employer did not ensure that each plank did not have more than 1 inch wide spacing between each unit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7986

1926.451 B04

Serious Gravity 10 1 instance 6 exposed
Issued
Nov 20, 2017
Abate by
Nov 27, 2017
Penalty
Initial $7,985 · Current $7,985
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).    (a)  Each end of a platform was not cleated or restrained and did not extend over the centerline support by at least 6 inches as required.
Recent events (2)
  • — I (S) $7985
  • — Z (S) $7985

1926.451 B07

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Nov 20, 2017
Abate by
Nov 27, 2017
Penalty
Initial $7,985 · Current $0 Reduced
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap was not at least 12 inches (30 cm) and the platforms were not nailed together or otherwise restrained to prevent movement:  (a) The employer did not ensure that the overlapping planks were at least 12 inches and that the platforms were nailed together or otherwise restrained to prevent movement where platforms were overlapped to create a long platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7985

View Superior Masonry Builders, INC.'s full OSHA safety record →