Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHUMASH CASINO RESORT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHUMASH CASINO RESORT in 3400 E. HIGHWAY 246, SANTA YNEZ, CA 93460 (NAICS 721120). OSHA activity number 342443959.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chumash Casino Resort — free Get an email when a new federal OSHA severe-injury report for Chumash Casino Resort is published. One employer, no account, unsubscribe in one click.
Site address
3400 E. HIGHWAY 246
City
SANTA YNEZ
State
CA
ZIP
93460
Mailing
3400 E. HIGHWAY 246, SANTA YNEZ, CA 93460
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
1400
Ownership type
A

16 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 12, 2017
Penalty
Initial $5,432 · Current $4,400 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) Hotel laundry room, building 3400:  No eye wash station within the work area of the laundry room for immediate emergency use was provided.  Three containers of Aqua Soil Buster corrosive chemicals and Clorox bleach were being used exposing employees to chemical or health hazards.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5432

1910.157 C01

Serious Gravity 1 2 instances 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $5,432 · Current $4,400 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    a) At the Control Room:  Ansul fire extinguisher was not mounted, located and identified. Employees had to maneuver around the shop table and other equipment to get access to the extinguisher, exposing employees to smoke or fire hazards.    b)  In the Tech Room:  Class A,B,C fire extinguisher was obstructed by a Ridgid wet vacuum cleaner and other materials.  Employees had to move the materials to get access to the fire extinguisher, exposing employees to smoke or fire hazards.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5432

1910.157 E02

Serious Gravity 1 2 instances 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly.  a) Security Area:  Amerex, Class A,B, and C fire extinguishers were not inspected at least monthly, the last inspection date was April 19, 2017.  Employees were exposed to smoke or fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $5,432 · Current $4,400 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i , nor was effective chip guarding and personal protective equipment used.    a) Upholstery Shop:  the compressed air pressure used for cleaning was not reduced to 30 psi.  The compressor air pressure gage was set to 120 psi which can force foreign matter to skin and into the blood stream. Employees were exposed to flying objects hazards.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5432

1910.303 B02

Serious Gravity 1 3 instances 6 exposed
Issued
Dec 4, 2017
Abate by
Dec 12, 2017
Penalty
Initial $5,432 · Current $4,400 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.    a) At the Security Area:  PAZ power panel circuit breakers 10 and 12 were taped together for receptacle circuit.  Employees were exposed to electrical shock hazards.    b) At the Upholstery Shop area:  re-locatable power tap used for cell phone and chargers was connected from an extension cord, exposing employees to electrical shock hazards.    c)  In the Engineering work station, Lite sun re-locatable power taps were daisy chained, one re-locatable power tap was connected to the other.  Employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5432

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage.   a) Hotel Electrical Room:  Boxes of materials, cleaning gear and other equipment were stored in the electrical room, thus reducing the working space and obstructing the energized electrical power panels.  Employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  a)  Floor OPS:  the extension cord used for battery chargers had been in its energized configuration for more than a year, temporary wiring was used in lieu of fixed wiring.  Employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.  a) Building 3400 Shop area:  The flexible power cord used for the shop power strip did not have strain relief.  The insulation was separating from the plug exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket.  a) In the TECH Room:  the red extension cord used for hand tools was missing it's ground pin.  Employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 4, 2017
Abate by
Dec 28, 2017
Penalty
Initial $5,432 · Current $4,400 Reduced
29 CFR 1910.1200(e)(1)(i): The hazard communication program did not include a list of hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.    a)  In building 3400, the employer did not have a complete inventory of all chemicals that were present in the workplaces such as Chemspec, rocket fuel carpet spray, Husky, uric acid all carpet rinse, Pro's Choice, acid rinse carpet cleaner, etc., exposing employees to chemical hazards.
Recent events (2)
  • — I (S) $4400
  • — Z (S) $5432

1910.1200 F05

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein.  a)  In the Tech Room:  a one gallon black container was not labeled or marked to indicate the identity of the hazards with using its contents.  Employees were exposed to chemical or health hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 4, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  a)  In building 3400, the employer did not have a complete safety data sheets of all chemicals that were present in the workplaces such as Chemspec, rocket fuel carpet spray, Husky, uric acid all carpet rinse, Pro's Choice, acid rinse carpet cleaner, etc., exposing employees to chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use.   a)  In the Bakery on the second floor, the door leading to the chocolate room was not marked "NOT AN EXIT".  Employees were exposed to smoke or fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.106 D05 III

Other-than-serious 1 instance 8 exposed
Issued
Dec 4, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(5)(iii): Storage of chemicals required and used for maintenance and operation of building and operation of equipment was not kept in closed metal containers stored in a flammable storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public.  a) Paint Storage, Carpet Repair and Shop Area:  Pro's Choice last step carpet cleaning acid rinse - textile rinse and anti-wicking agent, Chemspec Rocket Fuel High PH carpet pre-spray and other flammable chemicals were not kept inside the flammable storage cabinet.  Employees were exposed to smoke or fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.176 B

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage was not secure. Storage of material was not to create a hazard. Bags, containers, bundles, etc., stored in tiers were not be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.  a) Paint Storage area:  Suntouch brown boxes, Rust-oleum, epoxy floor coating and other materials were not properly stored on top of lockers, not stable and secured against sliding and collapsing.  Storage of materials created struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2017
Abate by
Dec 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  a)  At the Control Room, the Delta Shop Master Grinder designed for a fixed location, was not anchored to the floor to prevent walking or moving.  Employees were exposed to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Chumash Casino Resort's full OSHA safety record →