BELLEVILLE, IL —
OSHA Inspection: RODRIGUES SIDING AND ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RODRIGUES SIDING AND ROOFING LLC in 1841 LEBANON AVE. APARTMENT 4-12, BELLEVILLE, IL 62226 (NAICS 238160). OSHA activity number 342493939.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RODRIGUES SIDING AND ROOFING LLC
- Site address
- 1841 LEBANON AVE. APARTMENT 4-12
- City
- BELLEVILLE
- State
- IL
- ZIP
- 62226
- Mailing
- 809 COLLEGE MEADOWS RD, UNION, MO 63084
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jul 31, 2017
- Penalty
- Initial $3,259 · Current $1,630 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Head protective equipment was not used when workers were exposed to struck-by hazards when worker on the ground was working below unsecured tools and material on the roof.
Recent events (2)
- — I (S) $1630
- — Z (S) $3259
1926.102 A01
- Issued
- Jul 31, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: Eye protective equipment was not used when employees were exposed to eye injury while tearing off old roof shingles, and using pneumatic nail guns to install new roof shingles.
Recent events (2)
- — I (S) $1087
- — Z (S) $2173
1926.152 D04
- Issued
- Jul 31, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $2,716 · Current $0 Reduced
General-duty citation text
29 CFR 1926.152(d)(4): At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids: The employer did not ensure that a portable fire extinguisher was available to employees who were carrying a five (5) gallon gasoline can in the vehicle. The gasoline was being used to fill the air compressor.
Recent events (2)
- — I (S) $0
- — Z (S) $2716
1926.501 B13
- Issued
- Jul 31, 2017
- Penalty
- Initial $3,803 · Current $1,901 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: The employer did not ensure fall protection was implemented during residential construction operations when workers were exposed to the hazard of falling approximately twenty-four (24) feet off the roof eve when they were performing roofing operations.
Recent events (2)
- — I (S) $1901
- — Z (S) $3803
1926.1053 B01
- Issued
- Jul 31, 2017
- Abate by
- Aug 25, 2017
- Penalty
- Initial $3,803 · Current $1,901 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders are used for access to an upper landing surface and the ladder side rails do not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: The employer did not ensure portable ladders were constructed and placed so three (3) feet or more was extended above the upper landing. Workers performing residential construction were exposed to falling approximately twenty-four (24) feet while using an extension ladder to ascend/descend from the roof to the ground.
Recent events (2)
- — I (S) $1901
- — Z (S) $3803
More inspections at Rodrigues Siding and Roofing LLC
View Rodrigues Siding and Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342493939.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.