Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTOM SIGN CENTER, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUSTOM SIGN CENTER, INC. in 3200 VALLEYVIEW DR., COLUMBUS, OH 43204 (NAICS 339950). OSHA activity number 342498060.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Sign Center, INC. — free Get an email when a new federal OSHA severe-injury report for Custom Sign Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3200 VALLEYVIEW DR.
City
COLUMBUS
State
OH
ZIP
43204
Mailing
3200 VALLEYVIEW DR., COLUMBUS, OH 43204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
65
Ownership type
A

6 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 10 1 instance 10 exposed
Issued
Nov 15, 2017
Abate by
Dec 5, 2017
Penalty
Initial $8,873 · Current $5,324 Reduced
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.   a. On or about July 26, 2017, located in the flammable storage room, employees dispensed Kardol Acrylic Lacquer Thinner with a flashpoint of -4 degrees Fahrenheit from 55-gallon drums into plastic containers without the containers being grounded and bonded, thereby exposing the employees to an explosion/fire hazard.
Recent events (2)
  • — I (S) $5323.8
  • — Z (S) $8873

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 15, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.   a. On or about July 26, 2017, employees operated a table router that did not have any means of guarding to protect employees from the flying aluminum or polycarbonate chips, thereby exposing the employees eyes to struck-by hazard.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.242 B

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 15, 2017
Abate by
Dec 5, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.   a. On or about July 26, 2017, located at the router table employees used 89 p.s.i. of air to clean chips off the table and floor, thereby exposing the employees to being struck-by flying chips and/or air embolism.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.305 B01 II

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 15, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.     a. On or about July 26, 2017, located in the fabrication shop, there was an 240 volt, 3 phase electrical disconnect  that had an unused opening in the side of the disconnect box, thereby exposing employees to electrical shock and/or arc flash hazards.        b. On or about July 26, 2017,located in the fabrication shop, there was a 480 vac electrical panel along a wall that had an unused opening in the side of the panel box, thereby exposing employees to electrical shock and/or arc flash hazards.        c. On or about July 26, 2017, located in the back of the shipping department, there was a 480 vac electrical panel that had an unused opening in the upper side of the panel box, thereby exposing employees to electrical shock and/or arc flash hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.305 D02

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 15, 2017
Abate by
Dec 5, 2017
Penalty
Initial $6,338 · Current $0 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.       a. On or about July 26, 2017, there was a 480 electrical panel that was used in part to supply electrical power to a buss bar, Miller and Hobart welder, shop heater, etc. The electrical panel had a piece of polycarbonate as a means of a dead front, thereby exposing the employees to an arc flash incident.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6338

1910.305 G01 IV A

Deleted Repeat 1 instance 10 exposed
Issued
Nov 15, 2017
Abate by
Dec 5, 2017
Penalty
Initial $253 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:  29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;   a. On or about July 26, 2017, located in the Fabrication Department, there was a DeWalt miter saw, model number DWS780 that had an extension cord plugged into it that was being used as permanent wiring.   Custom Sign Center, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 967698, citation number 1, item number 1b and was affirmed as a final order on July 9, 2017, with respect to a workplace located at 3200 Valleyview Drive Columbus, Ohio 43204.
Recent events (2)
  • — I (R) $0
  • — Z (R) $253

View Custom Sign Center, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342498060.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.