COLUMBUS, OH —
OSHA Inspection: CUSTOM SIGN CENTER, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CUSTOM SIGN CENTER, INC. in 410 NORTH WILSON ROAD, COLUMBUS, OH 43204 (NAICS 339950). OSHA activity number 342849759.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM SIGN CENTER, INC.
- Site address
- 410 NORTH WILSON ROAD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43204
- Mailing
- 3200 VALLEYVIEW DR., COLUMBUS, OH 43204
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 70
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 12, 2018
- Abate by
- Feb 27, 2018
- Penalty
- Initial $6,467 · Current $6,467
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance. a. On or about December 26, 2017, and at time thereto, employees were performing servicing and maintenance covered activities on the robots in the robot building. The employer did not develop a documented energy control procedure for employees to utilize while performing tip changes on the welders, replacing and/or switching spools of wire, and cleaning the work area.
Recent events (1)
- — Z (S) $6467
1910.212 A01
- Issued
- Feb 12, 2018
- Abate by
- Mar 19, 2018
- Penalty
- Initial $9,054 · Current $9,054
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a. On or about December 19, 2017, and at times thereto, employees loaded and unloaded steel parts in the Fanuc M-16T overhead robotic welder cell. The presence sensing photoelectric devices across the openings of the barrier guarding were both damaged and bypassed, thereby exposing the employees to a struck by hazard. b. On or about December 26, 2017, and at times thereto, employees loaded and unloaded metal and aluminum parts in the Fanuc S-420F robotic welder cell. Employees were able to stand between the presence sensing photoelectric eyes and the jig table, while being undetected by the robot, thereby exposing the employees to a struck-by hazard.
Recent events (1)
- — Z (S) $9054
More inspections at Custom Sign Center, INC.
View Custom Sign Center, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339950)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342849759.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.