OSHA Inspection: CUSTOM SIGN CENTER, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUSTOM SIGN CENTER, INC. in 410 NORTH WILSON ROAD, COLUMBUS, OH 43204 (NAICS 339950). OSHA activity number 342849759.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Sign Center, INC. — free Get an email when a new federal OSHA severe-injury report for Custom Sign Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
410 NORTH WILSON ROAD
City
COLUMBUS
State
OH
ZIP
43204
Mailing
3200 VALLEYVIEW DR., COLUMBUS, OH 43204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
70
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 12, 2018
Abate by
Feb 27, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.   a. On or about December 26, 2017, and at time thereto, employees were performing servicing and maintenance covered activities on the robots in the robot building. The employer did not develop a documented energy control procedure for employees to utilize while performing tip changes on the welders, replacing and/or switching spools of wire, and cleaning the work area.
Recent events (1)
  • — Z (S) $6467

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Feb 12, 2018
Abate by
Mar 19, 2018
Penalty
Initial $9,054 · Current $9,054
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a. On or about December 19, 2017, and at times thereto, employees loaded and unloaded steel parts in the Fanuc M-16T overhead robotic welder cell. The presence sensing photoelectric devices across the openings of the barrier guarding were both damaged and bypassed, thereby exposing the employees to a struck by hazard.  b. On or about December 26, 2017, and at times thereto, employees loaded and unloaded metal and aluminum parts in the Fanuc S-420F robotic welder cell. Employees were able to stand between the presence sensing photoelectric eyes and the jig table, while being undetected by the robot, thereby exposing the employees to a struck-by hazard.
Recent events (1)
  • — Z (S) $9054

View Custom Sign Center, INC.'s full OSHA safety record →