Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SUMMIT UTILITY STRUCTURES, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of SUMMIT UTILITY STRUCTURES, LLC in 2027 S. 12TH ST. BUILDING 507, ALLENTOWN, PA 18103 (NAICS 332312). OSHA activity number 342500543.

Watch Summit Utility Structures, LLC — free Get an email when a new federal OSHA severe-injury report for Summit Utility Structures, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2027 S. 12TH ST. BUILDING 507
City
ALLENTOWN
State
PA
ZIP
18103
Mailing
225 KIWANIS BLVD, WEST HAZLETON, PA 18202
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
40
Ownership type
A

10 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5387.00 · Current $1519.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) 2027 S. 12th St. Building 507, Allentown, PA - on or about June 7, 2017, an employee performed servicing and maintenance on machinery and equipment to include but not limited to horizontal band saw, press brakes, and cranes where lock out/tagout hardware was used, but the employer had not developed, documented, and utilized procedures for the control of potentially hazardous energy.
Recent events (3)
  • — F (S) $1519
  • — C (S) $5387
  • — Z (S) $5387

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  a) 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, an employee performed servicing and maintenance on machinery and equipment to include but not limited to horizontal band saw, press brakes, and cranes where lock out/tagout hardware was used, but the employer had not provided adequate training to ensure that the purpose and function of the energy control program was understood.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.179 J02

Serious Gravity 10 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $2502.00 Reduced
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections:    a) 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the 5 ton, 10 ton, 7.5 ton, and 20 ton cranes did not receive daily to monthly inspections with certification, where required, of the items outlined in sections (j)(2)(I) through (j)(2)(iv) of this section.
Recent events (3)
  • — F (S) $2502
  • — C (S) $8873
  • — Z (S) $8873

1910.179 J01 I

Serious Gravity 5 1 instance 40 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(1)(i): Prior to initial use, all new and altered cranes were not inspected to insure compliance with the provisions of 29 CFR 1910.179(j).  a) 2027 S. 12th St. Building 507, Allentown, PA - on or about June 7, 2017, employees were lifting metal with a 7.5 Ton crane, which had not been inspected prior to use.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.184 D

Serious Gravity 5 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $5387.00 · Current $1519.00 Reduced
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:    a) 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the employer did not designate a competent person to inspect slings, all fastenings, and attachments for damage and defects each day before being used.
Recent events (3)
  • — F (S) $1519
  • — C (S) $5387
  • — Z (S) $5387

1910.212 A03 II

Serious Gravity 10 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $2502.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) South West Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the point of operation for two Cincinnati press brakes placed together were not guarded to prevent employees from having their hands and fingers in the danger zone during operating cycles.    b) North East Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the point of operation for the Durma press brake was not adequately guarded to prevent employees from having their hands in the danger zone during operating cycles.    c) Throughout; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the point of operation for the porta-power press brakes were not guarded to prevent employees from having their hands in the danger zone during operating cycles.
Recent events (3)
  • — F (S) $2502
  • — C (S) $8873
  • — Z (S) $8873

1910.252 B02 III

Serious Gravity 1 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $3231.00 · Current $920.00 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a) Throughout; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, employees working and walking in adjacent areas to welding operations were not protected from the rays by welding screens or shields.
Recent events (3)
  • — F (S) $920
  • — C (S) $3231
  • — Z (S) $3231

1910.305 B01 II

Serious Gravity 5 3 instances 40 exposed
Issued
Abate by
Penalty
Initial $5387.00 · Current $1519.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) North West Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the employer had a circuit breaker panel with seven (7) unused openings that were not effectively closed.    b) West Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the employer had a 480V circuit control panel with several unused openings that were not effectively closed.    c) South East Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the employer had a circuit breaker panel with one (1) unused opening that was not effectively closed.
Recent events (3)
  • — F (S) $1519
  • — C (S) $5387
  • — Z (S) $5387

1910.333 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5387.00 · Current $1519.00 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    a) 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, where maintenance employees work on internal electrical components of equipment which operates at 480V, the employer did not develop or implement safety-related work practices outlined in paragraphs (a) through (c) of this section.
Recent events (3)
  • — F (S) $1519
  • — C (S) $5387
  • — Z (S) $5387

1910.303 G01 II

Other-than-serious 1 instance 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) South West Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the working space about electric equipment was used for storage of items to include but not limited to a work bench, tools, and trash can.  b) South East Wall; 2027 South 12th St. Building 507, Allentown, PA - on or about June 7, 2017, the working space about electric equipment was used for storage of items to include but not limited to trash can and plasma cutting equipment.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View SUMMIT UTILITY STRUCTURES, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342500543.