Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PMM GLOBAL LLC

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of PMM GLOBAL LLC in 17 S. ROSELLE RD., SCHAUMBURG, IL 60193 (NAICS 238140). OSHA activity number 342503638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PMM Global LLC — free Get an email when a new federal OSHA severe-injury report for PMM Global LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PMM GLOBAL LLC
Site address
17 S. ROSELLE RD.
City
SCHAUMBURG
State
IL
ZIP
60193
Mailing
4908 N. NAGLE AVE., CHICAGO, IL 60630
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

11 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 8 exposed
Issued
Jan 9, 2018
Abate by
Feb 27, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  PMM Global, LLC did not provide the area office abatement certification and/or abatement documentation as required by the citation:  Citation Number                        Item Number                        Abatement Date 01                                            01a                                        10/31/2017                             01                                            01b                                        10/31/2017                             01                                            01c                                        10/31/2017                             01                                            01d                                        10/31/2017                             01                                            02a                                        10/31/2017                                01                                            02b                                        10/17/2017                             01                                            02c                                        10/31/2017                             02                                            01                                          10/31/2017                              In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $311

1910.134 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $2,988 · Current $2,988

Hazardous substances 0577S900

29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program, including worksite specific procedures and all applicable provisions of this section, in the workplace where respirators were required by the employer as necessary to protect the health of the employee.  a) On July 27, 2017, PMM Global LLC did not establish and implement a written respiratory protection program when employees mixing Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5) were required to wear a 3M 8210V or 8511 Particulate Respirator (N95).
Recent events (1)
  • — Z (S) $2988

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) On July 27, 2017, PMM Global LLC did not provide medical evaluations to determine employees' ability to wear 3M 8210V or 8511 Particulate Respirators (N95) before they were required to be used.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator is fit tested prior to initial use, whenever a different respirator facepiece (size, style, make or model) is used, and at least annually thereafter.  a) On July 27, 2017, PMM Global LLC did not ensure that employees were fit tested prior to requiring employees to use a full face tight-fitting negative pressure respirator.
Recent events (1)
  • — Z (S) $0

1910.134 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

29 CFR 1910.134(k)(1):  The employer did not provide effective respirator training that would ensure that each employee could demonstrate knowledge of items in section (i)-(vii).  a) On July 27, 2017, PMM Global LLC did not provide respirator training when employees were required to wear 3M 8210V or 8511 Particulate Respirators (N95) while mixing Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5) with sand and water.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $2,988 · Current $2,988

Hazardous substances 0577S900

NOTE: Construction Reference: 1926.59 The requirements applicable to construction work under this section are identical to those set forth at � 1910.1200 of this chapter.  29 CFR 1910.1200(e)(1):  PMM Global LLC did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) The employer did not develop a written hazard communication program in accordance with 29 CFR 1910.1200(e)(1) that would describe or include at least the following:    1) Requirement for labeling of containers of hazardous chemicals; 2) Material safety data sheet availability; 3) Training of employees; 4) A complete list of hazardous chemicals known to be present in the workplace; 5) Methods to inform employees of the hazards on non-routine tasks; and 6) Methods to inform other employer(s) of material safety data sheet availability; the labeling system and any precautionary measures to protect employees.  On July 27, 2017, employees of PMM Global LLC were exposed to hazardous materials, such as, but not limited to portland cement, when mixing Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5) with sand and water.
Recent events (1)
  • — Z (S) $2988

1910.1200 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 17, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

NOTE: Construction Reference: 1926.59 The requirements applicable to construction work under this section are identical to those set forth at � 1910.1200 of this chapter.  29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet (SDS) for each hazardous chemical which they used.  a) On July 27, 2017, PMM Global LLC did not ensure that a SDS was available for the masonry cement (Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5)) used by employees onsite.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 31, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

NOTE: Construction Reference: 1926.59 The requirements applicable to construction work under this section are identical to those set forth at � 1910.1200 of this chapter.  29 CFR 1910.1200(h)(1): The employer did not provide employees with information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area.  a) On July 27, 2017, PMM Global LLC did not did not ensure that employees were provided training when they were exposed to hazardous materials when mixing Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5).
Recent events (1)
  • — Z (S) $0

1926.100 A

Repeat Gravity 5 1 instance 1 exposed
Issued
Oct 4, 2017
Abate by
Oct 17, 2017
Penalty
Initial $5,976 · Current $5,976
29 CFR 1926.100(a): Employee(s) were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  a)  On July 27, 2017, an employee engaged in hoisting operations was exposed to struck-by hazards and not wearing a hard hat.  PMM Global LLC was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.100(a), which was contained in OSHA Inspection # 1109913, citation number 1, item number 1, and was affirmed as a final order on February 22, 2016, with respect to a workplace located at 3821 N. Southport Avenue in Chicago, IL 60613.
Recent events (1)
  • — Z (R) $5976

1926.95 A

Other-than-serious 1 instance 1 exposed
Issued
Oct 4, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided and not used wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:  a) On July 27, 2017, PMM Global LLC did not ensure that its employee wore appropriate hand protection when handling Essroc Cementi Brixment Type N Masonry Cement Type I (pH>11.5).   No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (O) $0

1926.102 A01

Other-than-serious 1 instance 1 exposed
Issued
Oct 4, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0577S900

29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) On July 27, 2017, PMM Global LLC did not ensure that employees wore appropriate eye protection when exposed to eye hazards resulting from the mixing of Essroc Cementi Brixment Type N Masonry Cement (pH > 11.5) with sand and water.  No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (O) $0

View PMM Global LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342503638.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.