CLEVELAND, OH —
OSHA Inspection: INTIGRAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INTIGRAL, INC. in 7850 NORTHFIELD ROAD, CLEVELAND, OH 44146 (NAICS 332321). OSHA activity number 342508934.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTIGRAL, INC.
- Site address
- 7850 NORTHFIELD ROAD
- City
- CLEVELAND
- State
- OH
- ZIP
- 44146
- Mailing
- 7850 NORTHFIELD ROAD, CLEVELAND, OH 44146
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 212
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.28 B01 I
- Issued
- Sep 8, 2017
- Penalty
- Initial $4,987 · Current $3,491 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: On or about July 3, 2017, the employer failed to ensure that the platform, which was located directly over the continuous tempering washer machine, was protected on the side of the stairs exposing employees to the hazard of a fall from a height greater than 4 feet. The platform was approximately 6 feet high.
Recent events (2)
- — I (S) $3490.9
- — Z (S) $4987
1910.147 C02 II
- Issued
- Sep 8, 2017
- Penalty
- Initial $10,267 · Current $7,187 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which renderedi the machine or equipment inoperative. On or about July 31, 2017, the employer did not ensure that employees were locking and tagging out machinery prior to them performing the task of clearing a jam. Machinery to include but not limited to the Continuous Tempering Washer.
Recent events (2)
- — I (S) $7186.9
- — Z (S) $10267
More inspections at Intigral, INC.