SHINNSTON, WV —
OSHA Inspection: UNIVERSAL ENTERPRISES, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNIVERSAL ENTERPRISES, INC in 91 ROOSEVELT ST, SHINNSTON, WV 26431 (NAICS 332312). OSHA activity number 342564747.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL ENTERPRISES, INC
- Site address
- 91 ROOSEVELT ST
- City
- SHINNSTON
- State
- WV
- ZIP
- 26431
- Mailing
- PO BOX 9, SHINNSTON, WV 26431
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 26
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 18, 2017
- Penalty
- Initial $3,879 · Current $2,909 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Craftsman 15inch Drill Press: On or about August 17, 2017 and times prior, employees used the Craftsman 15inch Drill press, Model # 137.229250, Serial Number RHN46, to drill holes in clips and key holes in fabricated pieces. The rotating drill bit was not provided with a shield guard to prevent employee exposure to the flying chips and rotating parts.
Recent events (2)
- — I (S) $2909.25
- — Z (S) $3879
1910.147 C06 I
- Issued
- Sep 18, 2017
- Abate by
- Nov 3, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about August 17, 2017 and times prior, employees performed servicing and maintenance activities such as equipment repairs, changing blades and greasing machines. The employer did not perform annual periodic inspections of the energy control program to ensure the requirements of the energy control standards are met.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Universal Enterprises, INC
View Universal Enterprises, INC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342564747.