Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WOODS ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WOODS ROOFING, INC. in 5429 N. MONITOR AVE., CHICAGO, IL 60630 (NAICS 238160). OSHA activity number 342580834.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Woods Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Woods Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WOODS ROOFING, INC.
Site address
5429 N. MONITOR AVE.
City
CHICAGO
State
IL
ZIP
60630
Mailing
2623 N. WEST ST., RIVER GROVE, IL 60171
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 14, 2017
Abate by
Sep 20, 2017
Penalty
Initial $3,803 · Current $2,500 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a)  On August 22, 2017, employees performing roofing work were exposed to fall hazards of approximately 14.5 feet and 22.5 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.552 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 14, 2017
Abate by
Sep 20, 2017
Penalty
Initial $3,803 · Current $2,500 Reduced
29 CFR 1926.552(a)(1):  The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators:       a)  On August 22, 2017, employees were observed climbing a material hoist which was not designed for use as a ladder.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 14, 2017
Abate by
Sep 20, 2017
Penalty
Initial $0 · Current $0
CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigged support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:     a)  On August 22, 2017, an extension ladder used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 7 exposed
Issued
Sep 14, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1):  The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:    a)  On August 22, 2017, the employer did not maintain records or certification of fall protection training for employees exposed to fall hazards.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Woods Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342580834.