Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BACZYNSKI MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BACZYNSKI MASONRY, INC. in 2918 N. LAKEWOOD AVE., CHICAGO, IL 60657 (NAICS 238140). OSHA activity number 342581212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baczynski Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Baczynski Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2918 N. LAKEWOOD AVE.
City
CHICAGO
State
IL
ZIP
60657
Mailing
1873 BENNETT PL, DES PLAINES, IL 60016
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 7, 2017
Abate by
Dec 13, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:    a)  On  August 23, 2017, employees working from frame scaffolding were exposed to fall hazards of greater than 25 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

1926.501 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 7, 2017
Abate by
Dec 13, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(3):  Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:  a)  On August 23, 2017, employees were exposed to fall hazards of greater than 25 feet while working in a hoist area.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

1926.501 B14

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 7, 2017
Abate by
Dec 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(14):  Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:  a) On August 23, 2017, employees were not protected from fall hazards of greater than 25 feet to the ground while working near an unprotected wall opening.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 7, 2017
Abate by
Dec 13, 2017
Penalty
Initial $1,630 · Current $1,630
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:  a)  On or about August 23, 2017, employees were using a job made ladder which did not extend 3 feet above the upper landing being accessed.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $1630

View Baczynski Masonry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342581212.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.