WHEAT RIDGE, CO —
OSHA Inspection: COLORADO STEEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COLORADO STEEL, INC. in 4836 VAN GORDON STREET, WHEAT RIDGE, CO 80033 (NAICS 332312). OSHA activity number 342644440.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLORADO STEEL, INC.
- Site address
- 4836 VAN GORDON STREET
- City
- WHEAT RIDGE
- State
- CO
- ZIP
- 80033
- Mailing
- 4836 VAN GORDON STREET, WHEAT RIDGE, CO 80033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about September 18, 2017, and at times prior, the employer did not ensure that a written respiratory protection program was established and implemented for required respirator use. An employee involved in painting activities, using chemicals such as Methyl Ethyl Ketone and Xylene, required to use a 3M 5200 half-face respirator was exposed to chemical inhalation hazards in that the employer did not establish and implement a written respiratory program that included among other requirements annual fit testing, medical evaluation and training. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.134 C02 I
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D of 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) On or about September 18, 2017, and at times prior, the employer did not ensure that respirator users were provided with the information contained in Appendix D of 29 CFR 1910.134 when the employer determined that voluntary respirator use was permissible. Employees in the shop were exposed to respiratory hazards while voluntarily using 3M 5200 half-face respirators in that precautions were not taken to ensure that the respirator itself did not present a hazard. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about September 18, 2017, and at times prior, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was required to use the respirator in the workplace. An employee involved in painting activities was exposed to respiratory hazards in that a medical evaluation was not conducted prior to the employee using a 3M model 5200 half-face respirator. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) On or about September 18, 2017, and at times prior, the employer did not ensure that employees using tight-fitting respirators were fit tested prior to initial use of the respirator. An employee involved in painting activities using a 3M 5200 half-face respirator was exposed to chemical inhalation hazards in that the employer did not conduct a fit test to ensure proper respirator fit prior to initial use. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) On or about September 18, 2017, and at times prior, the employer did not ensure that respirators were stored to protect them from damage, contamination, dust, extreme temperatures, and were not packed or stored to prevent deformation of the facepiece and exhalation valve. Employees using 3M 5200 half-face respirators were exposed to respiratory hazards in that their respirators were not properly stored to protect them from contamination, dust, extreme temperatures, damaging chemicals, deformation of the facepiece and exhalation valve. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I
- Issued
- Oct 6, 2017
- Abate by
- Nov 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: (a) On or about September 18, 2017, and at times prior, the employer did not ensure that electrical equipment had a work space clearance of at least 30 inches wide in front of such equipment. Access to electrical panels in the main shop was blocked by several 5-gal buckets of flammable liquids. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Colorado Steel, INC.
View Colorado Steel, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342644440.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.