Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAVIS-STANDARD, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DAVIS-STANDARD, LLC in 1 EXTRUSION DRIVE, PAWCATUCK, CT 06379 (NAICS 326199). OSHA activity number 342686417.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Davis-Standard, LLC — free Get an email when a new federal OSHA severe-injury report for Davis-Standard, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DAVIS-STANDARD, LLC
Site address
1 EXTRUSION DRIVE
City
PAWCATUCK
State
CT
ZIP
06379
Mailing
1 EXTRUSION DRIVE, PAWCATUCK, CT 06379
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
450
Ownership type
A

2 citations on file for this inspection.

1910.107 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 5, 2018
Abate by
Apr 19, 2018
Penalty
Initial $4,712 · Current $2,500 Reduced
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:    SPRAY COATING    On, or about, October 4, 2017, the flammable spray booth had material stored within the three foot clear space around the booth, which included, a flammable storage cabinet, storage lockers  that contained paper and other combustible material when employees used flammable materials, such as, but not limited to PPG AQUACRON Primer, which had a flash point  of 122F.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4712

1910.134 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 5, 2018
Abate by
Apr 19, 2018
Penalty
Initial $6,282 · Current $3,000 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    GRINDING    On, or about, December 13, 2017, an employee was not medically evaluated to determine the ability to wear a 3M, P100, half face, elastomeric respirator for voluntary use while performing grinding activities.