PAWCATUCK, CT —
OSHA Inspection: DAVIS-STANDARD, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DAVIS-STANDARD, LLC in 1 EXTRUSION DRIVE, PAWCATUCK, CT 06379 (NAICS 333249). OSHA activity number 343811238.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVIS-STANDARD, LLC
- Site address
- 1 EXTRUSION DRIVE
- City
- PAWCATUCK
- State
- CT
- ZIP
- 06379
- Mailing
- 1 EXTRUSION DRIVE, PAWCATUCK, CT 06379
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 470
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.178 A04
- Issued
- May 16, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $8,335 · Current $5,001 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly when modifications and additions which affect capacity and safe operation of powered industrial trucks: Production Floor: On, or about, March 7, 2019, tip hoppers were used throughout the facility to collect scrap. The tip hoppers were then transported using a forktruck to the waste collection area. The tip hopper observed in the Screw Department contained mild steel scrap, a relatively heavy material. The employer had not determined the safe load limit when tip hoppers were used with forktrucks in the facility.
Recent events (2)
- — I (S) $5001
- — Z (S) $8335
1910.212 A01
- Issued
- May 16, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $10,419 · Current $6,251 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: A. Fabrication Department: On, or about, March 7, 2019, a guard was not provided for the lower blade pulley on the Marvel band saw. B. Die Cell: On, or about, March 7, 2019, the rotating chip conveyor provided on the Kuraki KBT 13 milling center was not provided with safeguarding. It was located in the walking surface of the work platform and was operated with a standard on/off switch. C. Die Cell: On, or about, March 7, 2019, the Mazak Integrex 70 turning center was not provided with safeguarding such as an interlocked access door. D. Die Cell: On, or about, March 7, 2019, the Mazak Integrex 70YB turning center was not provided with safeguarding such as an interlocked access door. E. Die Cell: On, or about, March 7, 2019, safeguarding was not provided on the Okuma horizontal lathe lead screw. F. Die Cell: On, or about, March 7, 2019, safeguarding was not provided on lead screw on the large Okuma horizontal lathe, serial number 50140765. G. Screw Department: On, or about, March 7, 2019, safeguarding was not provided on the lead screw of the large Poreba horizontal lathe.
Recent events (2)
- — I (S) $6251.4
- — Z (S) $10419
1910.212 A03 II
- Issued
- May 16, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A. Fabrication Department: On, or about, February 25, 2019, an employee suffered multiple partial finger amputations while attempting to cut copper plate on the Large Allsteel Shear. The barrier guard provided on the shear was not installed in accordance with guard opening guidelines in that the opening left between the guard and bed of the shear allowed access to both the hold-downs and shear blade. B. Fabrication Department: On, or about, March 7, 2019, the barrier guard provided on the Small Allsteel Shear was not installed in accordance with guard opening guidelines to prevent access to the hold-downs. C. Fabrication Department: On, or about, March 7, 2019, guards were not provided on the angle cutting station of the Austin Hastings iron worker, Model 70W-1019. Also, the plexiglass guard provided at the hole punch allowed access to the point of operation.
Recent events (2)
- — I (S) $7956
- — Z (S) $13260
1910.213 H01
- Issued
- May 16, 2019
- Penalty
- Initial $10,419 · Current $6,251 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut: Shipping: On, or about, March 7, 2019, the adjustable lower blade guard provided on the Delta radial arm was stuck in the raised position.
Recent events (2)
- — I (S) $6251.4
- — Z (S) $10419
1910.213 H04
- Issued
- May 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator: Shipping: On, or about, March 7, 2019, the auto return mechanism provided for the Delta radial arm saw was not working.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- May 16, 2019
- Penalty
- Initial $5,314 · Current $3,188 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Die Cell: On, or about, March 7, 2019, a compressed air nozzle provided for use at the blue lathe and pedestal grinder was measured to be greater than 60 p.s.i., dead-ended.
Recent events (2)
- — I (S) $3188.4
- — Z (S) $5314
1910.303 G01 I A
- Issued
- May 16, 2019
- Penalty
- Initial $8,335 · Current $5,001 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: A. Fabrication Department: On, or about, March 7, 2019, a vertical support column for the underhung crane bridge was located 28 inch from the face of the Siemens panelboard that energized various equipment in the department. B. Test Area: On, or about, March 7, 2019, a compressed air hose reel stand had been installed in the working space for panelboard D-14.
Recent events (2)
- — I (S) $5001
- — Z (S) $8335
1910.303 G01 I B
- Issued
- May 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater : Fabrication Department: On, or about, March 7, 2019, a transformer was installed next to the GE panelboard, reducing the working space width to 18 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I C
- Issued
- May 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303: Fabrication Shop: On, or about, March 7, 2019, a transformer had been installed in the working space for the Siemens 600 volt panelboard. The transformer projected 10.5 inches from the face of the panelboard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- May 16, 2019
- Penalty
- Initial $5,314 · Current $3,188 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Production Floor, Machine #217: On, or about, March 7, 2019, an extension cord was used to energize a printer.
Recent events (2)
- — I (S) $3188.4
- — Z (S) $5314
1910.335 A01 I
- Issued
- May 16, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $10,419 · Current $6,251 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: Company: On, or about, March 7, 2019, personal protective equipment such as, but not limited to, voltage rated gloves, fire resistive clothing, face shields, balaclavas, hard hats and hearing protection was not worn by provided to employees who performed live electrical work, including trouble-shooting, or who verified that electrical equipment was properly de-energized.
Recent events (2)
- — I (S) $6251.4
- — Z (S) $10419
1910.215 B09
- Issued
- May 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Die Cell: On, or about, March 7, 2019, the tongue guard provided on the left side of the Delta pedestal grinder was not properly adjusted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Davis-Standard, LLC
View Davis-Standard, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333249)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343811238.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.