OSHA Inspection: FOREST SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREST SERVICE in 145 FOREST SERVICE RD, GIRDWOOD, AK 99587 (NAICS 115310). OSHA activity number 342695590.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Forest Service — free Get an email when a new federal OSHA severe-injury report for Forest Service is published. One employer, no account, unsubscribe in one click.
Establishment
FOREST SERVICE
Site address
145 FOREST SERVICE RD
City
GIRDWOOD
State
AK
ZIP
99587
Mailing
P.O. BOX 129, GIRDWOOD, AK 99587
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
40
Ownership type
D

4 citations on file for this inspection.

1910.334 A02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 22, 2018
Abate by
Mar 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Visitor's Center, back-up generator room:  On or about 11 October 2017 and times prior thereto, strain relief was not provided for a Avenger Steam Cleaner, Model AV12QX, serial number not legible. The outer protective jacket for the power supply cord was damaged in two locations. This condition exposed employees to electrical shock hazards and fire hazards.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV B

Repeat Gravity 1 1 instance 4 exposed
Issued
Feb 22, 2018
Abate by
Mar 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were used where run through holes in walls, ceilings, or floors.  Visitor's Center, Reception Area:  On or about 11 October 2017 and times prior thereto, a 25-foot energized beige colored extension cord was routed through a window opening and further routed through a doorway and plugged into a desktop lamp. This condition exposed employees to an electrical shock and electrical burn hazard and fire hazards.  The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(1)(iv)(B) which was contained in OSHA inspection number 987418, citation number 1, item number 3 and was affirmed as a final order on 03 September 2014, with respect to a workplace located at Kenai Lake Work Center in Seward, Alaska.
Recent events (1)
  • — Z (R) $0

1910.305 B01 II

Repeat Gravity 1 1 instance 4 exposed
Issued
Feb 22, 2018
Abate by
Mar 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  Visitor's center, atrium hallway:  On or about 11 October 2017 and times prior thereto, an energized electrical box was missing a knockout plug on the top portion of the faceplate. This condition exposed employees to an electrical shock hazard.     The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(b)(1)(ii), which was contained in OSHA inspection number 1069616, citation number 1 item number 8 and was affirmed as a final order on 22 July 2015, with respect to a workplace located at Cordova Ranger District in Cordova, Alaska.
Recent events (1)
  • — Z (R) $0

1910.305 G01 IV A

Repeat Gravity 1 1 instance 4 exposed
Issued
Feb 22, 2018
Abate by
Mar 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  Visitor's Center, Reception Area:  On or about 11 October 2017 and times prior thereto, a 25-foot energized beige colored extension cord was used as a substitute for permanent wiring. This condition exposed employees to an electrical shock and electrical burn hazard.  The U.S. Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(1)(iv)(A) which was contained in OSHA inspection number 1069616, citation number 1, item number 9 and was affirmed as a final order on 22 July 2015, with respect to a workplace located at Cordova Ranger District located in Cordova, Alaska.
Recent events (1)
  • — Z (R) $0