MARYLAND HEIGHTS, MO —
OSHA Inspection: M.B. STURGIS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of M.B. STURGIS INC. in 11722 NORTHLINE INDUSTRIAL DRIVE, MARYLAND HEIGHTS, MO 63043 (NAICS 332912). OSHA activity number 342698321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M.B. STURGIS INC.
- Site address
- 11722 NORTHLINE INDUSTRIAL DRIVE
- City
- MARYLAND HEIGHTS
- State
- MO
- ZIP
- 63043
- Mailing
- 11722 NORTHLINE INDUSTRIAL DRIVE, MARYLAND HEIGHTS, MO 63043
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332912
- Employees
- 72
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 24, 2017
- Abate by
- Dec 12, 2017
- Penalty
- Initial $6,338 · Current $3,169 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At 11722 Northline Industrial Drive, Maryland Heights, MO, specifically inside of the Maintenance Shop on 10/16/17, the rotating parts belonging to the following machines were unguarded: a/ Alliant Milling Machine, m/n 5 TMV, s/n 72042380. b/ Lathe. c/ Craftsman 20" Drill Press. d/ Central Machinery Lathe.
Recent events (2)
- — I (S) $3169
- — Z (S) $6338
1910.305 B02 I
- Issued
- Oct 24, 2017
- Abate by
- Dec 12, 2017
- Penalty
- Initial $3,802 · Current $1,901 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose: At 11722 Northline Industrial Drive, specifically inside of the Maintenance Shop, one dual receptacle box with a missing face plate was providing power to a lathe. This violation was observed on 10/16/17.
Recent events (2)
- — I (S) $1901
- — Z (S) $3802
More inspections at M.B. Sturgis INC.
View M.B. Sturgis INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332912)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342698321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.