MAGNOLIA, TX —
OSHA Inspection: S&R WATERPROOFING AND ROOFING, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of S&R WATERPROOFING AND ROOFING, LLC in 11659 FM 1488, MAGNOLIA, TX 77354 (NAICS 238160). OSHA activity number 342699733.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S&R WATERPROOFING AND ROOFING, LLC
- Site address
- 11659 FM 1488
- City
- MAGNOLIA
- State
- TX
- ZIP
- 77354
- Mailing
- 2500 CENTRAL PKWY STE. A, HOUSTON, TX 77092
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.502 G03 II
- Issued
- Nov 14, 2017
- Penalty
- Initial $6,338 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(g)(3)(ii): Each line was not rigged and supported in such a way that its lowest point is not less than 39 inches from the walking/working surface. On or about October 11, 2017 at the construction site where the rope of the warning system was not rigged and supported at 39 inches from the walking/working surface.
Recent events (2)
- — I (S) $0
- — Z (S) $6338
1926.502 H01
- Issued
- Nov 14, 2017
- Penalty
- Initial $6,338 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(h)(1): The employer did not did not designate a competent person to monitor the safety of other employees and/or did not ensure that the safety monitor complied with the requirements listed in (h)(1)(i) through (h)(1)(v) of this section: On or about October 11, 2017 at the construction site where the employer did not designate a competent person to monitor the safety of other employees.
Recent events (2)
- — I (S) $0
- — Z (S) $6338
1926.1053 B01
- Issued
- Nov 14, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. On or about October 11, 2017 at the construction site where employees were exposed to fall hazards when accessing the upper landing surface with a portable ladder that was not secured at the top.
Recent events (2)
- — I (S) $0
- — Z (S) $3802
1910.1200 E01
- Issued
- Nov 14, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) On or about October 11, 2017, at the construction site, where employees were using chemicals such as, propane, without a written hazard communication program in place.
Recent events (2)
- — I (S) $0
- — Z (S) $3802
1910.1200 G01
- Issued
- Nov 14, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) On or about October 11, 2017, at the construction site, where employees were using chemicals such as, propane and had not been trained on the hazards of the chemicals they use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Nov 14, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $3,802 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical which they used: (Construction Reference: 1926.59) On or about October 11, 2017 at the construction site, where employees did not have a safety data sheet for the propane that was in use.
Recent events (2)
- — I (S) $0
- — Z (S) $3802
More inspections at S&R Waterproofing and Roofing, LLC
View S&R Waterproofing and Roofing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342699733.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.