Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTEPLAST GROUP CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTEPLAST GROUP CORPORATION in 5 OTIS ST, WESTBOROUGH, MA 01581 (NAICS 326113). OSHA activity number 342750643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inteplast Group Corporation — free Get an email when a new federal OSHA severe-injury report for Inteplast Group Corporation is published. One employer, no account, unsubscribe in one click.
Site address
5 OTIS ST
City
WESTBOROUGH
State
MA
ZIP
01581
Mailing
PO BOX 624, WESTBOROUGH, MA 01581
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
Employees
55
Ownership type
A

9 citations on file for this inspection.

1910.147 C05 II

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $6,097 · Current $0 Reduced
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy:    (a) Site: On a 480 volt circuit panel in the center of the facility, 5 Otis Street, Westborough, MA 01581 on 2/14/2018 and at times earlier lockout devices were used to prevent employees from interrupting production operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6097

1910.147 C06 I

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $12,934 · Current $6,467 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    (a) Site: In the facility, 5 Otis Street, Westborough, MA 01581 on 2/18/2018 and at times earlier the employer did not conduct a periodic inspection of the Small Erema energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.
Recent events (2)
  • — I (S) $6467
  • — Z (S) $12934

1910.147 C08

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance:    (a) Site: In the production area, Small Erema, 5 Otis Street, Westborough, MA 01581 on or about 11/22/2017 and at times earlier the Small Erema was locked out by a LOTO authorized employee and the servicing or maintenance associated with the lock out was performed by a different employee (a machine operator) who was not a LOTO authorized employee.    (b) Site: In the facility production area, Line 11, 5 Otis Street, Westborough, MA 01581 on 2/12/2018 and at times earlier the Automatic Scrap Regrinder (ASR) was locked out by a LOTO authorized employee and the servicing or maintenance associated with the lock out was performed by a different employee (a machine operator) who was not a LOTO authorized employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12934

1910.178 L04 III

Serious Gravity 5 3 instances 10 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $8,130 · Current $4,065 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a) Site: In the facility, 5 Otis Street, Westborough, MA 01581 on 12/19/2017 at least 3 of 10 active powered industrial truck (PIT) operators ran PITs and had not received an evaluation of their performance within the preceding three years.
Recent events (2)
  • — I (S) $4065
  • — Z (S) $8130

1910.178 L06

Serious Gravity 5 3 instances 10 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) Site: In the facility, 5 Otis Street, Westborough, MA 01581 on 12/19/2017, At least 3 of 10 active powered industrial truck (PIT) operators ran PITs without an employer certification that each operator had been trained and evaluated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 F01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $6,097 · Current $3,049 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  (a) Site: In the center of the facility, 5 Otis Street, Westborough, MA 01581 on 11/28/2017 and at times earlier overcurrent devices for circuits rated 600 volts, nominal, or less, were blocked by file cabinets, shelving units and other equipment such that they were not readily accessible to each employee or authorized building management personnel.
Recent events (2)
  • — I (S) $3048.5
  • — Z (S) $6097

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $10,163 · Current $5,082 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Site: In the facility production area, Upper Mezzanine, Zone 2, Line 13, 5 Otis Street, Westborough, MA 01581 on 2/14/2018 and at times flexible cords and cables for the hopper/loader/blender was not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — I (S) $5081.5
  • — Z (S) $10163

1910.147 C04 II

Repeat Gravity 5 1 instance 2 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $50,815 · Current $25,408 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  Site: In the facility, 5 Otis Street, Westborough, MA 01581 on 2/14/2018 and at times earlier the Energy Control procedure for the Small Erema did not contain:   (a) A specific statement of the intended use of the procedure; (b)  Specific procedural steps for each method of electrical isolation (i.e. local and at the main, control circuit (110volt) and main supply (480 volt)) and when it is required;  (c) Specific procedural steps for dissipating thermal energy (temperatures from 0-608 degrees Fahrenheit) in the reclaimer and when it is required; (d) Specific procedural steps for isolation of pneumatic energy (0-58 psi) and when it is required; (e) Specific steps to secure the mechanical energy (rotation) of the blade assembly (i.e. blocking) in the reclaimer; (f) Specific steps outlining the correct sequencing of hazardous energy isolation (what is deenergized, first/last, what is reenergized first/last); (g) Specific steps to identify and remove/replace all guards in the proper sequence; (h) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them (which EEs, e.g. mechanics, electricians, production technicians, machine operators, etc.  any or all) and; (i) Specific requirements for testing the Small Erema to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. Inteplast Group Limited was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1910.147(c)(4)(ii)), which was contained in OSHA inspection number 976716, citation number 1, item number 1 and was affirmed as a final order on 6/20/2014, with respect to a workplace located at   455 Somerset Avenue, North Dighton, MA 02764.
Recent events (2)
  • — I (R) $25407.5
  • — Z (R) $50815

1910.147 C07 I A

Repeat Gravity 5 2 instances 1 exposed
Issued
Apr 5, 2018
Abate by
Apr 17, 2018
Penalty
Initial $50,815 · Current $25,408 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation  (a) Site: In the production area, Small Erema, 5 Otis Street, Westborough, MA 01581 in mid-November 2017 and at times earlier, machine operators serviced the Small Erema Machine by performing tasks such as, but not limited to, clearing jams without having received required training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  (b) Site: In the facility production area, Line 11, 5 Otis Street, Westborough, MA 01581 on 2/12/2018 and at times earlier machine operators serviced the Automatic Scrap Regrinder (ASR) by performing tasks such as, but not limited to, setting up for color changes without having received required training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.   Inteplast Group Limited was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1910.147(c)(7)(I)(A), which was contained in OSHA inspection number 976716, citation number 1, item number 2 and was affirmed as a final order on 6/20/2014, with respect to a workplace located at   455 Somerset Avenue, North Dighton, MA 02764.
Recent events (2)
  • — I (R) $25407.5
  • — Z (R) $50815

View Inteplast Group Corporation's full OSHA safety record →