SCRANTON, PA —
OSHA Inspection: UNITED GILSONITE LABORATORIES INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of UNITED GILSONITE LABORATORIES INC. in 1396 JEFFERSON AVENUE, SCRANTON, PA 18501 (NAICS 325510). OSHA activity number 342769163.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED GILSONITE LABORATORIES INC.
- Site address
- 1396 JEFFERSON AVENUE
- City
- SCRANTON
- State
- PA
- ZIP
- 18501
- Mailing
- POST OFFICE BOX 70, SCRANTON, PA 18501
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 40
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C05 I
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $8,149 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) Building One, in floor mixing tanks A through D: Clamshell type, or other devices capable of isolating supply air line valves and oil feed valves of the air over hydraulic lift system were not available, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2: Clamshell type, or other devices capable of isolating supply air line valves and oil feed valves of the air over hydraulic lift system were not available, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $8000
- — Z (S) $8149
1910.147 F03 II D
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed by a multi person crew and each authorized employee of the crew did not affix his own personal lock to a lockout hasps, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed by a multi person crew and each authorized employee of the crew did not affix his own personal lock to a lockout hasps, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed by a multi person crew and each authorized employee of the crew did not receive training relative to the tasks that were performed, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed by a multi person crew and each authorized employee of the crew did not receive training relative to the tasks that were performed, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 D03 III
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $4,889 · Current $4,889
8450M110X100
General-duty citation text
1910.146(d)(3)(iii): Means and procedures used to effectively isolate the permit space were not implemented: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space and valves which controlled the inflow of liquids were not effectively isolated either by clamshell device, or other means, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space and valves which controlled the inflow of liquids were not effectively isolated either by clamshell device, or other means, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4889
- — Z (S) $4889
1910.146 D02
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
8450M110X100
General-duty citation text
1910.146(d)(3)(iv): Means and procedures used to effectively ventilate the permit space as necessary to eliminate or control atmospheric hazards were not developed: 1910.146(d)(2): Hazards of permit spaces were not identified and evaluated before employees entered the spaces: a) Building One, in floor mixing tanks A through C, all potential hazards within the mixing tanks were not evaluated prior to entry, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, all potential hazards within the mixing tanks were not evaluated prior to entry, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 B03 II A
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.304(b)(3)(ii)(A): 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that were temporary wiring, not part of the permanent wiring of the building or structure, were used by personnel during certain maintenance activities and were not equipped with ground-fault circuit-interrupter protection for personnel: a) Building One, in floor mixing tanks A through C, a 120 VAC incandescent bulb trouble light used inside the tanks during cleaning was powered by an extension cord, and no GFCI was present in either the outlet or within an in-line device, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 H01
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
8450M110X100
General-duty citation text
1910.146(h)(1): The employer did not ensure that all authorized entrants knew the hazards that may be faced during entry, including information on the mode, signs or symptoms, and consequences of the exposure: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space, and it was not ensured that all authorized entrants were knowledgeable of the hazards that may be present and the physical and health symptoms that may be signs of a hazardous condition, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space, and it was not ensured that all authorized entrants were knowledgeable of the hazards that may be present and the physical and health symptoms that may be signs of a hazardous condition, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C05 I C
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $4,889 · Current $0 Reduced
8450M110X100
General-duty citation text
1910.146(c)(5)(i)(C): Entry into a permit space was performed under alternate procedures specified in paragraph (c)(5)(i) of this section and monitoring and inspection data that supported the demonstrations required by paragraphs (c)(5)(i)(A) and (c)(5)(i)(B) of this section was not developed: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space, and no monitoring and inspection data was developed, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space, and no monitoring and inspection data was developed, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $4889
1910.146 C05 II H
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
8450M110X100
General-duty citation text
1910.146(c)(5)(ii)(H): Entry into a permit space was performed and the employer did not verify that the space was safe for entry and that the pre-entry measures required by paragraph (c)(5)(ii) of this section had been taken, through a written certification that contained the date, the location of the space, and the signature of the person providing the certification: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space, and no written certifications of safe entry conditions were made, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space, and no written certifications of safe entry conditions were made, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K01 III B
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $4,889 · Current $2,000 Reduced
8450M110X100
General-duty citation text
1910.146(k)(1)(iii)(B): Rescue and emergency services were designated for rescue and it was not ensured that the service was equipped for and proficient in performing the needed rescue services: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space, and it was not determined if the responding services were equipped with specialized equipment that may be needed to address the presence of small entry holes in the tanks, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space, and it was not determined if the responding services were equipped with specialized equipment that may be needed to address the presence of small entry holes in the tanks, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $4889
1910.146 K01 IV
- Issued
- Jan 5, 2018
- Abate by
- Feb 9, 2018
- Penalty
- Initial $0 · Current $0
8450M110X100
General-duty citation text
1910.146(k)(1)(iv): Rescue and emergency services were designated for rescue and each rescue team was not informed of the hazards they may confront when called on to perform rescue at the site: a) Building One, in floor mixing tanks A through C, cleaning maintenance was performed within a permit space, and the responding services were not informed of the hazards that could be present at a time of rescue, on or about, October 9, 2017. b) Building Two, in floor mixing tanks 1 and 2, cleaning maintenance was performed within a permit space, and the responding services were not informed of the hazards that could be present at a time of rescue, on or about, October 9, 2017. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at United Gilsonite Laboratories INC.
View United Gilsonite Laboratories INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342769163.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.