Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ZARBANA ALUMINUM EXTRUSION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ZARBANA ALUMINUM EXTRUSION, LLC in 41738 ESTERLY DR, COLUMBIANA, OH 44408 (NAICS 331318). OSHA activity number 342884301.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Zarbana Aluminum Extrusion, LLC — free Get an email when a new federal OSHA severe-injury report for Zarbana Aluminum Extrusion, LLC is published. One employer, no account, unsubscribe in one click.
Site address
41738 ESTERLY DR
City
COLUMBIANA
State
OH
ZIP
44408
Mailing
41738 ESTERLY DR, COLUMBIANA, OH 44408
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331318
Employees
52
Ownership type
A

8 citations on file for this inspection.

1910.25 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2018
Abate by
Jul 5, 2018
Penalty
Initial $3,880 · Current $2,134 Reduced
29 CFR 1910.25(c)(2): In addition to paragraph (b) of this section, the employer must ensure standard stairs have a maximum riser height of 9.5 inches (24 cm):       On or about January 6, 2018, the employer failed to ensure employees had a safe means of accessing the rack system on the 9 inch extruder press line, in that, employees had to climb approximately 28 inches to access the equipment.
Recent events (3)
  • — F (S) $2134
  • — C (S) $3880
  • — Z (S) $3880

1910.147 C04 I

Serious Gravity 10 2 instances 4 exposed
Issued
Jun 20, 2018
Abate by
Jul 10, 2018
Penalty
Initial $9,054 · Current $4,980 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about January 11, 2018, the employer failed to ensure written lockout/tagout procedures were developed to protect employees who enter the 7 and 9 inch aluminum extruders to perform cleaning, maintenance and apply wax to the press.
Recent events (3)
  • — F (S) $4979.7
  • — C (S) $9054
  • — Z (S) $9054

1910.147 F03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 20, 2018
Abate by
Jul 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew:    On or about January 6, 2018, the employer failed to ensure employees working inside the 9 inch aluminum extruder performing maintenance and adding machine guarding were protected by ensuring group lockout tagout procedures were created and followed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 7 exposed
Issued
Jun 20, 2018
Abate by
Jul 10, 2018
Penalty
Initial $9,054 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    On or about January 11, 2018, the employer did not ensure employees maintaining, cleaning, and applying wax to the 7 and 9 inch aluminum extrusion presses were trained as authorized employees under the control of hazardous energy standard.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 20, 2018
Abate by
Jul 25, 2018
Penalty
Initial $9,054 · Current $4,980 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, and flying chips:    On or about January 11, 2018, the employer failed to ensure employees entering the aluminum extruder were protected against:    1. Struck by hazards while unjamming moving stock on the rail system and walking through rolling stock to exit the equipment.     2. Crushing hazards from the die while applying wax.
Recent events (3)
  • — F (S) $4979.7
  • — C (S) $9054
  • — Z (S) $9054

1910.305 G01 I

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 20, 2018
Abate by
Jul 2, 2018
Penalty
Initial $9,054 · Current $4,980 Reduced

Hazardous substances 8870

29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location:    On or about January 11, 2018, the employer failed to ensure extension cords lying in water were approved to be utilized in wet conditions.
Recent events (3)
  • — F (S) $4979.7
  • — C (S) $9054
  • — Z (S) $9054

1910.305 G01 IV A

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 20, 2018
Abate by
Jul 2, 2018
Penalty
Initial $9,054 · Current $4,980 Reduced

Hazardous substances 8870

29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about January 11, 2018, the employer did not ensure that the heater for the caustic tank had permanent wiring supplying power in lieu of an extension cord.
Recent events (3)
  • — F (S) $4979.7
  • — C (S) $9054
  • — Z (S) $9054

1910.305 G02 II

Serious Gravity 10 1 instance 10 exposed
Issued
Jun 20, 2018
Abate by
Jul 2, 2018
Penalty
Initial $9,055 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    On or about January 11, 2018, the employer did not ensure that multiple extension cords were not plugged into each other to supply power to the heater for the caustic tank.
Recent events (3)
  • — F (S) $0
  • — C (S) $9055
  • — Z (S) $9055

View Zarbana Aluminum Extrusion, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342884301.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.