Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NANOGATE JAY SYSTEMS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NANOGATE JAY SYSTEMS, LLC in 150 E. LONGVIEW AVE, MANSFIELD, OH 44903 (NAICS 336399). OSHA activity number 342892130.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nanogate JAY Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Nanogate JAY Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
150 E. LONGVIEW AVE
City
MANSFIELD
State
OH
ZIP
44903
Mailing
515 NEWMAN ST., MANSFIELD, OH 44902
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
462
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I

Other-than-serious Gravity 5 1 instance 20 exposed
Issued
Mar 22, 2018
Abate by
Apr 4, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    Nanogate Jay Systems, LLC - Mansfield, Ohio:  On or about December 28, 2017, a periodic inspection of the energy control procedures was not performed to assure that lockout/tagout procedure and requirements of 29 CFR 1910.147 were being followed.  The employer did not assure that the energy control procedure for the #27 Engel molding press (s/n 208536) was inspected.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9239

1910.147 C07 I

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 22, 2018
Abate by
Apr 4, 2018
Penalty
Initial $9,239 · Current $4,619 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    Nanogate Jay Systems, LLC - Mansfield, Ohio: On or about December 28, 2017, the employer did not ensure that employees who maintain/clean molding machines such as, but not limited to, the #27 Engel molding machine (s/n 208536), were trained in the skills required for the safe application, usage, and removal of energy controls.  Employees who cleaned the machines were not trained to isolate and/or render energy sources safe.
Recent events (2)
  • — I (S) $4619
  • — Z (S) $9239

1910.147 D

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 22, 2018
Abate by
Apr 4, 2018
Penalty
Initial $9,239 · Current $4,619 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    Nanogate Jay Systems, LLC - Mansfield, Ohio: On or about December 28, 2017, employees were exposed to crushing and struck-by injuries in that the #27 Engel molding machine (s/n 208536) was not deenergized prior to servicing tasks such as, but not limited to, cleaning the machine.  The employer did not ensure that energy control application steps were implemented to control hazardous electrical/hydraulic and pneumatic energy sources of the machine's platen and associated parts picker; prior to the servicing task - the employer did not:  - Ensure employees had the method or means to control hazardous energy.  - Physically operate energy isolating devices and affix lockout device(s) to control the energy source(s).   - Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
  • — I (S) $4619
  • — Z (S) $9239

1910.178 N06

Serious Gravity 5 1 instance 23 exposed
Issued
Mar 22, 2018
Abate by
Apr 9, 2018
Penalty
Initial $7,391 · Current $3,696 Reduced
29 CFR 1910.178(n)(6): Industrial truck drivers were not required to look in the direction of, and keep a clear view of the path of travel:    Nanogate Jay Systems, LLC - Mansfield, Ohio: On or about January 19, 2018, employees in the E-brite 6 section were exposed to struck-by hazards in that the employer did not ensure that forklift operators had a clear view of the path of travel while transporting packaging boxes to molding machines.  Forklift operators travel forward with the load blocking their view to deliver the boxes to employees in the area.
Recent events (2)
  • — I (S) $3696
  • — Z (S) $7391

1910.212 A01

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 22, 2018
Abate by
Apr 9, 2018
Penalty
Initial $9,239 · Current $4,619 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Nanogate Jay Systems, LLC - Mansfield, Ohio: On or about January 19, 2018, employees were exposed to struck-by injuries in that the parts picker arm associated with the #24 molding machine was not guarded.
Recent events (2)
  • — I (S) $4619
  • — Z (S) $9239

1910.242 B

Serious Gravity 1 1 instance 50 exposed
Issued
Mar 22, 2018
Penalty
Initial $5,543 · Current $2,771 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Nanogate Jay Systems, LLC - Mansfield, Ohio: On or about January 19, 2018, compressed air was used in excess of 60 psi to clean debris from fiberglass parts at the E-brite Line 5 Destat area, exposing employees to embedding particles in their skin or eyes.
Recent events (2)
  • — I (S) $2771
  • — Z (S) $5543

View Nanogate JAY Systems, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342892130.