Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NANOGATE JAY SYSTEMS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NANOGATE JAY SYSTEMS, LLC in 150 E. LONGVIEW AVE, MANSFIELD, OH 44903 (NAICS 336390). OSHA activity number 345287924.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nanogate JAY Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Nanogate JAY Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
150 E. LONGVIEW AVE
City
MANSFIELD
State
OH
ZIP
44903
Mailing
515 NEWMAN ST., MANSFIELD, OH 44902
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
374
Ownership type
A

4 citations on file for this inspection.

1910.132 D01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2021
Abate by
Oct 26, 2021
Penalty
Initial $9,753 · Current $0 Reduced

Hazardous substances 00400435044015602150

CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  a)	Nanogate Jay Systems, LLC. located at 150 East Longview Avenue in Mansfield, Ohio; On or about May 4, 2021 the employer did not ensure that a hazard assessment identifying and selecting appropriate personal protective equipment was conducted prior to engaging in maintenance and paint cleaning in the e-brite line paint line 1 basecoat booth. Employees entering the paint line booth were exposed to hazardous solvents including Acetone, Butyl Acetate, Isopropyl Alcohol, Diethylene glycol monobutyl ether, Ethanol, 2-butoxy , Glycine, N,N'-1,2-ethanediylbis[N-(carboxymethyl)-, sodium salt (1:4), -Hexadecanamine, N,N-dimethyl-, N-oxide, 2-propanol, Sodium hydroxide (Na(OH)), and propane. Those chemicals can pose a wide range of health and physical hazards such as severe irritation, sensitization, and harm to the eyes (stinging, tearing, redness, swelling, and blurred vision.), skin, specific target organ toxicity, single exposure category 3 narcotic effects, intoxication, drowsiness, dizziness, headache, nausea, and vomiting. Prolonged inhalation may be harmful, may cause irritations to the respiratory tract.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9753

1910.134 D01 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2021
Abate by
Oct 26, 2021
Penalty
Initial $0 · Current $0

Hazardous substances 00400435044015602150

29 CFR  1910.134(d)(1)(i):The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker is exposed and workplace and user factors that affect respirator performance and reliability.  a)	Nanogate Jay Systems, LLC. located at 150 East Longview Avenue in Mansfield, Ohio; On or about May 4, 2021 employees were exposed to  hazardous solvents containing Acetone, Butyl Acetate, Isopropyl Alcohol, Diethylene glycol monobutyl ether, Ethanol, 2-butoxy , Glycine, N,N'-1,2-ethanediylbis[N-(carboxymethyl)-, sodium salt (1:4), -Hexadecanamine, N,N-dimethyl-, N-oxide, 2-propanol, Sodium hydroxide (Na(OH)), propane and its vapor without appropriate respiratory protection while engaging in maintenance and paint cleaning in the e-brite paint line 1 basecoat booth. Employees performing the regular weekly cleaning inside the paint booth were not assigned any type of respirator with filtering face piece that provides protection against chemical vapors. Those chemicals can pose a wide range of health and physical hazards such as severe irritation, sensitization, and harm including intoxication, drowsiness, dizziness, headache, nausea, and vomiting. Prolonged inhalation may be harmful, and may cause irritations to the respiratory tract.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.136 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 29, 2021
Abate by
Oct 26, 2021
Penalty
Initial $13,653 · Current $6,827 Reduced
29 CFR  1910.136(a):General requirements. The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, or when the use of protective footwear will protect the affected employee from an electrical hazard, such as a static-discharge or electric-shock hazard, that remains after the employer takes other necessary protective measures.  a)	Nanogate Jay Systems, LLC. located at 150 East Longview Avenue in Mansfield, Ohio; On or about May 4, 2021, the employer failed to ensure that each affected employee use protective footwear when working in the e-brite line area where there is a danger of foot injuries due to falling or rolling parts racks.
Recent events (2)
  • — I (S) $6826.5
  • — Z (S) $13653

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 29, 2021
Abate by
Oct 26, 2021
Penalty
Initial $13,653 · Current $6,827 Reduced
CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a)	Nanogate Jay Systems, LLC. located at 150 East Longview Avenue in Mansfield, Ohio; On or about May 4, 2021, the employer did not ensure that energy control application steps to control pneumatic energy sources were implemented prior to performing maintenance and paint cleaning in the e-brite line paint line 1 basecoat booth. Employees entering the paint line booth were inside the working zone of the robotic arm of an energized Yaskawa spraying robot, thereby exposed to struck-by hazards and rotating equipment injuries in that energy sources were not isolated.
Recent events (2)
  • — I (S) $6826.5
  • — Z (S) $13653

View Nanogate JAY Systems, LLC's full OSHA safety record →