Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COPPER CONSTRUCTION COMPANY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of COPPER CONSTRUCTION COMPANY, INC. in 410 MCINTOSH STREET, VIDALIA, GA 30474 (NAICS 332322). OSHA activity number 342916921.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Copper Construction Company, INC. — free Get an email when a new federal OSHA severe-injury report for Copper Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
410 MCINTOSH STREET
City
VIDALIA
State
GA
ZIP
30474
Mailing
410 MCINTOSH STREET, VIDALIA, GA 30474
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
55
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $6,467 · Current $3,234 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gasses in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965:     a) In the fabrication yard, on or about and at times prior to January 30, 2018, the employer did not ensure cylinders of compressed gasses were secured and protected from falling, exposing employees to explosion and fire hazards.
Recent events (2)
  • — I (S) $3233.5
  • — Z (S) $6467

1910.253 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) In the fabrication yard, on or about and at times prior to January 30, 2018, the employer did not ensure compressed gas cylinders were capped, exposing employees to explosion and fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating:  a) In the fabrication yard, on or about and at times prior to January 30, 2018, the employer did not ensure cylinders of acetylene and oxygen were stored separately at distances of at least 20 feet apart, exposing employees to explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) In the welding shop, on or about and at times prior to January 30, 2018, the employer did not provide employees, who voluntarily wore 3M filtering face-piece respirators, with the information contained in Appendix D, exposing employees to respiratory related hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  a) In the main office,  on or about and at times prior to January 30, 2018, the employer did not maintain the Safety Data Sheets for chemicals such as, but not limited to, acetylene used by employees during the course of their work day, exposing employees to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Mar 26, 2018
Abate by
Apr 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) In the fabrication area, on or about and at times prior to January 30, 2018, the employer did not provide employees with training on the chemicals used by employees during the course of their work, exposing employees to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Copper Construction Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342916921.