Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MICELI DAIRY PRODUCTS CO

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MICELI DAIRY PRODUCTS CO in 2721 E. 90TH ST., CLEVELAND, OH 44104 (NAICS 311513). OSHA activity number 342925203.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miceli Dairy Products CO — free Get an email when a new federal OSHA severe-injury report for Miceli Dairy Products CO is published. One employer, no account, unsubscribe in one click.
Site address
2721 E. 90TH ST.
City
CLEVELAND
State
OH
ZIP
44104
Mailing
2721 E. 90TH ST., CLEVELAND, OH 44104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
190
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 6, 2018
Penalty
Initial $11,641 · Current $5,821 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.      On or about January 25, 2018, the employer did not ensure energy control procedures were utilized when a sanitation worker performed service and maintenance (cleaning) operations on the mozzarella cheese curd line dicer machine.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $11641

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:   On or about January 25, 2018, the employer did not ensure a sanitation worker performing service and maintenance (cleaning) operations on the mozzarella cheese curd line dicer machine implemented energy control procedures by; preparing the machine for shutdown [per 1910.147(d)(1) requirements], turning off the machine [(d)(2)], isolating the machine from the energy source [(d)(3)], affixing a lockout device [(d)(4)(i)], and verifying de-energization and isolation had been accomplished prior to cleaning the machine [(d)(6)].
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 6 instances 3 exposed
Issued
Apr 6, 2018
Abate by
May 2, 2018
Penalty
Initial $11,641 · Current $5,821 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    On or about January 25, 2018, the employer did not conduct periodic inspections of the energy control procedures to ensure authorized employees who performing service and maintenance (cleaning and repairs) operations on the mozzarella cheese curd line and other machines and equipment used in the production of cheese were following the procedures and the requirements of the standard for energy isolation and control.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $11641

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 6, 2018
Abate by
May 2, 2018
Penalty
Initial $11,641 · Current $5,821 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.     On or about January 25, 2018, the employer did not ensure a sanitation worker authorized to perform service and maintenance (cleaning) operations on the mozzarella cheese curd line dicer machine received training in the recognition of hazardous energy sources, the type and magnitude of the energy available, and the methods and means necessary for energy isolation and control.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $11641

View Miceli Dairy Products CO's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342925203.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.