Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRINCE INDUSTRIES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRINCE INDUSTRIES INC. in 1050 KINGSLAND DR, BATAVIA, IL 60510 (NAICS 332322). OSHA activity number 342933702.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prince Industries INC. — free Get an email when a new federal OSHA severe-injury report for Prince Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
1050 KINGSLAND DR
City
BATAVIA
State
IL
ZIP
60510
Mailing
1050 KINGSLAND DR, BATAVIA, IL 60510
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
41
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2018
Abate by
Sep 30, 2018
Penalty
Initial $7,484 · Current $4,115 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     Press Brake Dept.  On or about February 7, 2018 through March 7, 2018, the employer had not documented machine-specific lockout/tagout procedures for the control of hazardous energy sources when maintenance employees were assigned servicing and maintenance tasks on the press brakes.   Employees were exposed to crushing hazards likely to result in amputation to hands and fingers from unexpected start up and/or energy release.        Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $4115
  • — Z (S) $7484

1910.212 A03 II

Serious Gravity 10 3 instances 4 exposed
Issued
Jul 17, 2018
Abate by
Aug 8, 2018
Penalty
Initial $10,477 · Current $5,762 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):       On or about January 29, 2018 through March 7, 2018, the point of operation on each of the following machines was not guarded, exposing employees to amputation, crushing and laceration hazards:       a.  Amada 80 Ton Press Brake (MN FaBIII-8025, SN 80250172)     b.  Baykal Fabline 200 Ton Press Brake (MN 02-2010, SN 15232)     c.  Amada 35 Ton Press Brake (MN RG 3512LD, SN 35120027)       Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $5762
  • — Z (S) $10477

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $7,484 · Current $4,116 Reduced
29 CFR 1910.332(b)(1):  Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments:     Entire Facility - On or about February 7, 2018 through March 7, 2018, maintenance employee(s) performed troubleshooting and servicing tasks on electrical components, including voltage testing on energized components from 110v to 480v.  Employee(s) were not trained in and familiar with safety-related work practices such as the use of special precautionary techniques, personal protective equipment (PPE), insulated tools and insulating and shielding materials necessary to safely accomplish such tasks.  Employees were exposed to the hazards of electrocution and arc flash/blast injuries.       Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $4116
  • — Z (S) $7484

1910.333 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:      Entire Facility - On or about February 7, 2018 through March 7, 2018, maintenance employee(s) performed troubleshooting and servicing tasks on electrical components, including voltage testing on energized components from 110v to 480v. The employer did not ensure that employee(s) were qualified persons, capable of working safely through familiarity with special precautionary techniques, personal protective equipment, insulating and shielding materials and insulated tolls necessary to safety accomplish such tasks.  Employee(s) were exposed to the hazards of electrocution and arc flash/blast injuries.      Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(c)(1): Only qualified persons may perform testing work on electric circuits or equipment:     Entire Facility - On or about February 7, 2018 to March 7, 2018, maintenance employee(s) who were not qualified persons were assigned and permitted to perform voltage testing on energized components.  Employees were exposed to the hazards of electrocution and arc flash/blast injuries.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2018
Abate by
Aug 8, 2018
Penalty
Initial $7,484 · Current $4,117 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:             Entire Facility - On or about February 7, 2018 through March 7, 2017, the employer did not ensure that maintenance employee(s) who performed work on or near energized electrical components, including voltage testing, were provided with and used electrical protective equipment for the face, head, hands and body to protect against burns, electrocution and arc flash/blast injuries.      Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).     Note: For abatement assistance, refer to 29 CFR 1910.137, "Electrical Protective Equipment", www.osha.gov; and national consensus standard NFPA 70E, "Standard for Electrical Safety in the Workplace", www.nfpa.org.
Recent events (2)
  • — I (S) $4117
  • — Z (S) $7484

View Prince Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342933702.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.