Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRONG CONTRACTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STRONG CONTRACTORS, INC. in 601 CHRISTIAN STREET, PHILADELPHIA, PA 19147 (NAICS 238130). OSHA activity number 342955366.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strong Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Strong Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 CHRISTIAN STREET
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
501 CAMBRIA AVENUE SUITE 193, BENSALEM, PA 19020
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
50
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2018
Abate by
Jul 30, 2018
Penalty
Initial $49,796 · Current $49,796
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure:  a) Jobsite: Employees working on top of wood framing were not provided fall protection; thus exposing them to approximately 20 foot fall hazard.  Condition was observed on or about 14 FEB 2018.  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1263810, citation number 2, item number 1, and was affirmed as a final order on 30 NOV 2017, with respect to a workplace located at 315 Cedarwood Court Manchester Township, NJ 08759  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1258009, citation number 1, item number 3, and was affirmed as a final order on 20 DEC 17, with respect to a workplace located at 5 James Drive Mount Laurel, NJ 08054  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1255453, citation number 2, item number 1, and was affirmed as a final order on 30 NOV 2017, with respect to a workplace located at 31 Langport dr.Heritage @ Medford Medford, NJ 08055  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1248058, citation number 1, item number 2, and was affirmed as a final order on 3 OCT 2017, with respect to a workplace located at 270 Gordon Rd. Robbinsville, NJ 08691  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1246134, citation number 2, item number 1, and was affirmed as a final order on 30 NOV 2017, with respect to a workplace located at 2 Milton Avenue Lakewood, NJ 08701  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1241542, citation number 1, item number 1, and was affirmed as a final order on 19 JAN 2018, with respect to a workplace located at 2649 Amber Street Philadelphia, PA 19125  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1240659, citation number 1, item number 1, and was affirmed as a final order on 29 NOV 2017, with respect to a workplace located at 2649 Amber Street Philadelphia, PA 19125  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10) which was contained in OSHA inspection number 1240522, citation number 1, item number 1/a, and was affirmed as a final order on 20 DEC 2017, with respect to a workplace located at 1733 Reed Street Philadelphia, PA 19146  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1229431, citation number 1, item number 3, and was affirmed as a final order on 15 SEP 2017, with respect to a workplace located at 1528 W Girard Ave Philadelphia, PA 19130  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13) which was contained in OSHA inspection number 1219850, citation number 1, item number 3, and was affirmed as a final order on 23 MAY 2017, with respect to a workplace located at Valley lot 3 And 4 Center Valley, PA 18034
Recent events (1)
  • — Z (R) $49796

1926.503 A01

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2018
Abate by
Sep 4, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a) Jobsite: Employees building frames for a residential building were not provided fall protection training; thus exposing them to fall hazards.  Condition was observed on or about 14 FEB 2018.   Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1) which was contained in OSHA inspection number 1246134, citation number 1, item number 2, and was affirmed as a final order on 30 NOV 2017, with respect to a workplace located at 2 Milton Avenue Lakewood, NJ 08701  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1) which was contained in OSHA inspection number 1241542, citation number 1, item number 1, and was affirmed as a final order on 19 JAN 2018, with respect to a workplace located at 2649 Amber Street Philadelphia, PA 19125  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1) which was contained in OSHA inspection number 1240522, citation number 1, item number 1/b, and was affirmed as a final order on 20 DEC 2017, with respect to a workplace located at 1733 Reed Street Philadelphia, PA 19146  Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.503(a)(1) which was contained in OSHA inspection number 1229431, citation number 1, item number 4, and was affirmed as a final order on 15 SEP 2017, with respect to a workplace located at 1528 W Girard Ave Philadelphia, PA 19130
Recent events (1)
  • — Z (R) $0

1926.1051 A

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2018
Abate by
Jul 30, 2018
Penalty
Initial $49,796 · Current $49,796
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided:  a) Jobsite: The employer did not ensure that the ladder provided at the jobsite was a safe means of access to the working level approximately 10 feet from the ground surface.  Condition was observed on or about 14 FEB 2018.    Strong Contractor, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1051(a) which was contained in OSHA inspection number 1219850, citation number 1, item number 4/a, and was affirmed as a final order on 23 MAY 2017, with respect to a workplace located at Valley lot 3 And 4 Center Valley, PA 18034
Recent events (1)
  • — Z (R) $49796

View Strong Contractors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342955366.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.