Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURO FIBER CO., INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DURO FIBER CO., INC. in 11 PARK AVENUE, HUDSON, NH 03051 (NAICS 313210). OSHA activity number 342962222.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Duro Fiber CO., INC. — free Get an email when a new federal OSHA severe-injury report for Duro Fiber CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 PARK AVENUE
City
HUDSON
State
NH
ZIP
03051
Mailing
11 PARK AVENUE, HUDSON, NH 03051
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313210
Employees
10
Ownership type
A

11 citations on file for this inspection.

1910.107 C05

Serious Gravity 5 2 instances 8 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $2,217 · Current $1,110 Reduced
29 CFR 1910.107(c)(5): 29 CFR 1910.107(c)(5):  Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s):    a. Gelcoat Spray Area - On or about February 20, 2018, deposits of Advance Coatings Company 379 Gelcoat, a category 3 flammable liquid, had accumulated on a halogen light and extension cord which were not approved for use in Class I locations.  Employees were exposed to fire hazards.    b. Gelcoat and Fiber-Resin Spray Areas - On or about February 20, 2018, deposits of 4510 MVP Class 1 Fire Retardant Low Emission Resin, a category 3 flammable liquid, had accumulated on electric switches, outlets, conduit, and extension cords which were not approved for use in Class I locations.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $1110
  • — Z (S) $2217

1910.107 G02

Serious Gravity 5 1 instance 8 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary, and tool(s) used for cleaning purposes in spraying areas were not of non-sparking material:  a. Gelcoat Spray Area - On or about February 20, 2018, deposits of Advance Coatings Company 379 Gelcoat, a category 3 flammable liquid, had accumulated on the floor, walls, and ventilation opening.  Employees were exposed to fire hazards.    b. Fiber-Resin Spray Area - On or about February 20, 2018, deposits of 4510 MVP Class 1 Fire Retardant Low Emission Resin, a category 3 flammable liquid, had accumulated on the floor, walls, and ventilation opening to depths exceeding 4 inches.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G03

Serious Gravity 5 2 instances 8 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(3): Residue scrapings and debris contaminated with residue were not immediately removed from the premises and properly disposed. Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing material; and all such rags or waste were not deposited therein immediately after use. The contents of waste cans were not properly disposed of at least once daily or at the end of each shift:   a. Gelcoat Prep Area - On or about February 20, 2018, waste cups and cleaning rags contaminated with Advance Coatings Company 379 Gelcoat were not placed into approved metal waste cans.  Employees were exposed to fire hazards.      b. In Front of the Fiber-Resin Spray Area - On or about February 20, 2018, waste cuttings of 4510 MVP Class 1 Fire Retardant Low Emission Resin were not placed into approved metal waste cans.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G05

Serious Gravity 5 1 instance 8 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $2,772 · Current $1,400 Reduced
29 CFR 1910.107(g)(5): 29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints greater than 100 degrees Fahrenheit; or for cleaning spray nozzles and auxiliary equipment, solvents with flashpoints less than those normally used in spray operations were used:     a. Gelcoat Prep Area - On or about February 20, 2018, acetone with a flashpoint of 1.4 degrees Fahrenheit was used as a cleaning solvent for 379 Gelcoat with a flashpoint of 89 degrees Fahrenheit.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2772

1910.132 D02

Serious Gravity 5 1 instance 4 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $2,772 · Current $1,400 Reduced
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:    a. Fiber-Resin Spray Area - On or about February 20, 2018, the employer failed to conduct personal protective equipment (PPE) hazard assessment for preparing and spraying a mixture of NOROX MEKP-925 Red and 4510 MVP Class 1 Fire Retardant Low Emission Resin.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2772

1910.133 A01

Serious Gravity 5 1 instance 4 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a. Fiber-Resin Spray Area - On or about February 20, 2018, employees were required to prepare and spray a mixture of NOROX MEKP-925 Red and 4510 MVP Class 1 Fire Retardant Low Emission Resin, and the employer failed to ensure that safety goggles or glasses with side shields were worn.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $2,217 · Current $1,110 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    a. Gelcoat Spray Area - On or about February 20, 2018, the employer failed to ensure that the written program included the requirements necessary to ensure employees voluntarily wearing 1/2 face air purifying respirators during gelcoat spraying operations were medically able to use the respirators.
Recent events (2)
  • — I (S) $1110
  • — Z (S) $2217

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a. Gelcoat Spray Area - On or about February 20, 2018, the employer failed to provide medical evaluations to determine employee ability to wear 1/2 face air purifying respirators during gelcoat spraying operations
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 1 1 instance 4 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $1,663 · Current $1,350 Reduced
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:    a. Fiber-Resin Spray Area - On or about February 20, 2018, the employer failed to require the use of chemical resistant gloves for preparing and spraying a mixture of NOROX MEKP-925 Red and 4510 MVP Class 1 Fire Retardant Low Emission Resin.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $1663

1910.1200 F06

Serious Gravity 5 2 instances 5 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $2,772 · Current $1,400 Reduced
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) or (f)(6)(ii) of this section:    a. Gelcoat Prep Area - On or about February 20, 2018, an employee was required to measure and pour NOROX MEKP-30 into gelcoat, and the employer failed to ensure that the container was labeled.      b. Fiber-Resin Spray Area - On or about February 20, 2018, an employee was required to use acetone to clean the chopper gun, and the employer failed to ensure that the container was labeled.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2772

1910.107 G07

Other-than-serious 1 instance 8 exposed
Issued
May 1, 2018
Abate by
May 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not posted at all spraying areas and paint storage rooms.   a. Spray and Flammable Liquid Storage Areas - On or about February 20, 2018, No Smoking signs were not posted.