OSHA Inspection: TROY LAMINATING AND COATING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TROY LAMINATING AND COATING, INC. in 421 S UNION ST, TROY, OH 45373 (NAICS 322220). OSHA activity number 342984671.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy Laminating and Coating, INC. — free Get an email when a new federal OSHA severe-injury report for Troy Laminating and Coating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
421 S UNION ST
City
TROY
State
OH
ZIP
45373
Mailing
421 S UNION ST, TROY, OH 45373
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322220
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 4 instances 10 exposed
Issued
Aug 13, 2018
Abate by
Dec 31, 2018
Penalty
Initial $7,114 · Current $7,960
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    (a)  The periodic inspection of the energy control program was inadequate, in that it did not include a review of each machine specific procedure for each type of equipment, to include the slitters, coaters, compressors and rewinders.
Recent events (2)
  • — I (S) $7960
  • — Z (S) $7114

1910.147 C07 I

Repeat Gravity 10 10 instances 10 exposed
Issued
Aug 13, 2018
Abate by
Dec 31, 2018
Penalty
Initial $19,918 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i):  The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:       (a)  Employees cleaning the rubber roll on the release station on the #475 Coater Line, were not adequately trained on the energy control program, such as when and how to attach locks to the energy isolating devices, prior to cleaning the rubber roll.      (b)  Employees cleaning the blade and bar on the Wintech rewinder on the #475 Coater Line, were not adequately trained on the energy control program, such as when and how to attach locks to the energy isolating devices, prior to cleaning the blade and the bar.      Troy Laminating and Coating, Inc. was previously cited for a violation of this occupational safety and health standard, or its equivalent standard, which was contained in OSHA inspection number 892734, Citation Number 2, Item Number 2 and was affirmed as a final order on August 21, 2013, with respect to a workplace located at 421 S. Union Street, Troy, OH 45373.
Recent events (2)
  • — I (R) $0
  • — Z (R) $19918

1910.147 D

Repeat Gravity 10 10 instances 10 exposed
Issued
Aug 13, 2018
Abate by
Dec 31, 2018
Penalty
Initial $19,918 · Current $0 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:    (a)  On or about Feb 22, 2018, employees cleaning the rubber roll on the release station on the #475 Coater Line, were not required to: turn off and shut down the machines, physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the electric, pneumatic and vacuum energy sources, affix lockout or tagout devices to each energy isolating device.      (b)  Employees cleaning the blade and bar on the Wintech rewinder on the #475 Coater Line, were not required to: turn off and shut down the machines, physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the electric, pneumatic and vacuum energy sources, affix lockout or tagout devices to each energy isolating device.          Troy Laminating and Coating, Inc. was previously cited for a violation of this occupational safety and health standard, or its equivalent standard, which was contained in OSHA inspection number 892734, Citation Number 1, Item Number 1 and Citation 2, Item 3, and was affirmed as a final order on August 21, 2013, with respect to a workplace located at 421 S. Union Street, Troy, OH 45373.
Recent events (2)
  • — I (R) $0
  • — Z (R) $19918

View Troy Laminating and Coating, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342984671.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.