OSHA Inspection: TROY LAMINATING AND COATING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TROY LAMINATING AND COATING, INC. in 421 S. UNION STREET, TROY, OH 45373 (NAICS 322220). OSHA activity number 343880597.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy Laminating and Coating, INC. — free Get an email when a new federal OSHA severe-injury report for Troy Laminating and Coating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
421 S. UNION STREET
City
TROY
State
OH
ZIP
45373
Mailing
421 S. UNION STREET, TROY, OH 45373
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322220
Employees
58
Ownership type
A

6 citations on file for this inspection.

1910.22 D01

Serious Gravity 10 1 instance 2 exposed
Issued
May 21, 2019
Abate by
Jun 24, 2019
Penalty
Initial $10,210 · Current $4,000 Reduced
29 CFR 1910.22(d)(1):  Walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition;    a) On 3/18/2019 the employer did not ensure that the decking was completed on the back side of the #18 coater, two employees were in the process of cleaning excess coating from an oven, the employees were cleaning the backside of the oven while standing on the oven vents and a support beam, employee #1 had finished cleaning a spot on the oven and went to step off of the vent piping onto the beam, as the employee stepped down the employee missed the beam and fell through an opening in the decking of 2 ft. X 4 ft. the employee fell approximately 5 ft. to the concrete floor below the oven vents.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $10210

1910.28 B15

Serious Gravity 10 1 instance 2 exposed
Issued
May 21, 2019
Abate by
Jun 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(15): (15) Walking-working surfaces not otherwise addressed.  Except as provided elsewhere in this section or by other subparts of 29 CFR part 1910, the employer must ensure each employee on a walking-working surface 4 feet (1.2 m) or more above a lower level is protected from falling by:  i) Guardrail system ii) Safety net systems; or iii) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.   a) On 3/18/2019 the employer did not ensure that employees working on the backside of the #18 Coater machine  were protected from a fall of greater than 4 ft. Two employees were climbing on the backside of the machine cleaning excess coating out of the oven,  an employee stepped off of an oven vent and fell through a opening in the deck of about 2 ft. X 4 ft. The employee fell approximately 5 ft. to the concrete floor. The employees were not protected from falling to a lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.30 A01

Serious Gravity 10 1 instance 2 exposed
Issued
May 21, 2019
Abate by
Jun 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(1): (a) Fall hazards. (1) Before any employee is exposed to a fall hazard, the employer must provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart.  Employers must ensure employees are trained in the requirements of this paragraph on or before May 17, 2017.  a) On 3/26/2019 the employer did not ensure that employees were properly trained on utilizing fall protection systems to ensure employees understand the hazards associated with working aloft above 4 ft. to prevent falls, two employees were climbing on the backside of the machine cleaning excess coating out of the oven,  employee #1 stepped off of an oven vent and fell through a deck opening of 2 ft. X 4 ft. The employee fell approximately 5 ft. to the concrete floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C01

Serious Gravity 5 1 instance 2 exposed
Issued
May 21, 2019
Abate by
Jun 24, 2019
Penalty
Initial $7,293 · Current $1,000 Reduced
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces.   NOTE: Proper application of the decision flow chart in Appendix A to section 1910.146 would facilitate compliance with this requirement.    a) On 3/26/2019 the employer did not evaluate the workplace to determine if the Coater ovens through-out the facility were properly labeled as permit-required confined spaces.   Employees enter the ovens to clean excess coating from inside the ovens.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $7293

1910.146 G01

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2019
Abate by
Jun 24, 2019
Penalty
Initial $7,293 · Current $1,000 Reduced
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section.    a) On 3/26/2019 the employer did not ensure employees were properly trained to understand the hazards associated with the permit required confined space.  Employees get into ovens to remove excess coating from inside of the ovens.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $7293

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2019
Penalty
Initial $7,293 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    a) On 3/26/2019 employees were exposed to electrical shock due to live wires of greater than 50 volts hanging from different electrical components such as, but not limited to the control instruments for a control panel located on the backside platform of the oven and a control sensor for the Co2 fire suppression system located under the backside of the oven platform.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $7293