Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE PALLET PLACE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE PALLET PLACE, LLC in 25158 W INTERSTATE 20, VAN, TX 75790 (NAICS 321920). OSHA activity number 343015996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Pallet Place, LLC — free Get an email when a new federal OSHA severe-injury report for The Pallet Place, LLC is published. One employer, no account, unsubscribe in one click.
Site address
25158 W INTERSTATE 20
City
VAN
State
TX
ZIP
75790
Mailing
25158 W. INTERSTATE 20, VAN, TX 75790
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 2 instances 4 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $9,959 · Current $6,500 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    a)On or about March 13, 2018 employees were exposed to a amputation hazard of the double head machine 1 and 2 when performing energy control procedures and not identifying air as a power source.    b)On or about March 12, 2018 and time prior to employer did not identify and utilize group energy control procedures when installing guards or replacing cutting blades on double head machine.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9959

1910.147 F03 II D

Serious Gravity 10 1 instance 5 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $9,959 · Current $6,500 Reduced
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.    On or about March 12, 2018 and times prior to employees did not affix a personal lockout device to the group Lockout device when installing guards  and performing maintenance on double head, Newman KM-16 and notcher.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9959

1910.212 A01

Serious Gravity 10 1 instance 5 exposed
Issued
May 9, 2018
Abate by
Jul 5, 2018
Penalty
Initial $9,959 · Current $6,500 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    On March 13, 2018 and times prior to employees were exposed to amputation hazard on Newman Km-16 #1 and 2 when employees would hold on to the wood until the saw starts to cut.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9959

1910.213 A09

Serious Gravity 10 3 instances 6 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $9,959 · Current $6,500 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of 1910.219.    a)On March 13, 2018 and time prior to employees were exposed of amputation hazard by pulleys and belts not guarded on the Notcher machine.     b)On March, 13, 2018 and times prior to employees were exposed to amputation hazards when the pulley and belt were not guarded on the blower motor next to the notcher.     c)On March 19, 2018 and times prior to employees were exposed to amputation hazard when pulleys and belts were not guarded on KM-16#1 and KM-16#2
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9959

1910.219 C02 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $9,959 · Current $6,500 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    On march 13, 2018 and times prior to employees were exposed to caught in hazard when shafts at approximately 30 inches from the ground were not guarded on the double head saw #1 and 2.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9959

1910.219 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.   On march 13, 2018 and times prior to employees were exposed to hazard with projecting shafts were not guarded on the double head saw #1 and 2.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 9, 2018
Abate by
Jun 5, 2018
Penalty
Initial $7,114 · Current $4,616 Reduced
29 CFR 1910.335(a)(2)(ii): Protective shields, protective barriers, or insulating materials shall be used to protect each employee from shock, burns, or other electrically related injuries while that employee is working near exposed energized parts which might be accidentally contacted or where dangerous electric heating or arcing might occur. When normally enclosed live parts are exposed for maintenance or repair, they shall be guarded to protect unqualified persons from contact with the live parts.    On March 13, 2018 and times prior to employees were expose to electric hazard when applying energy control procedures on notcher machine by opening the electric cabinet with 440 volts.
Recent events (2)
  • — I (S) $4616
  • — Z (S) $7114

View The Pallet Place, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343015996.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.