On , OSHA opened a follow-up health inspection of THE PALLET PLACE, LLC in 25158 W. INTERSTATE 20, VAN, TX 75790 (NAICS 321920). OSHA activity number 343019634.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PALLET PLACE, LLC
- Site address
- 25158 W. INTERSTATE 20
- City
- VAN
- State
- TX
- ZIP
- 75790
- Mailing
- 25158 W. INTERSTATE 20, VAN, TX 75790
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 40
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.22 A01
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $5,691 · Current $3,700 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: On or about March 13, 2018 and at times prior thereto employees were exposed to fire hazards from accumulations of wood dust on the following surfaces: (a) Walls near the two headed notcher; (b) Walls near the Wood-Mizer 5 head saw; (c) Walls near the Newman KM16 #2 saw; (d) Over-head light fixtures near the two headed notcher; (e)Over-head light fixtures near Wood-Mizer 5 head saw; (f) Over-head light fixtures near the Newman KM16 #2 saw; (g)Over-head light fixtures near the Wood-Mizer 6 head saw; (h) Over-head cables near the two headed notcher; (i) Over-head cables near the Wood-Mizer 6 head saw; (j) Over-head metal rafters throughout the woodshop; (k) Fire extinguishers near the two headed notcher; (l) Metal poles with the disconnect near the Newman KM16 #3 saws; (m) Over-head compressed air lines near the two headed notcher; (n) Over-head compressed air lines near Wood-Mizer 5 head saw; (o) Other surfaces throughout the woodshop.
Recent events (2)
- — I (S) $3700
- — Z (S) $5691
1910.141 A03 I
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed On or about March 13, 2018 and at times prior thereto employees were exposed to fire hazards from accumulations of wood dust on the following surfaces: (a) Walls near the two headed notcher; (b) Walls near the Wood-Mizer 5 head saw; (c) Walls near the Newman KM16 #2 saw; (d) Over-head light fixtures near the two headed notcher; (e)Over-head light fixtures near Wood-Mizer 5 head saw; (f) Over-head light fixtures near the Newman KM16 #2 saw; (g)Over-head light fixtures near the Wood-Mizer 6 head saw; (h) Over-head cables near the two headed notcher; (i) Over-head cables near the Wood-Mizer 6 head saw; (j) Over-head metal rafters throughout the woodshop; (k) Fire extinguishers near the two headed notcher; (l) Metal poles with the disconnect near the Newman KM16 #3 saws; (m) Over-head compressed air lines near the two headed notcher; (n) Over-head compressed air lines near Wood-Mizer 5 head saw; (o) Other surfaces throughout the woodshop.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $5,691 · Current $0 Reduced
9135W103
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about March 22, 2018 and at times prior thereto the employer did not establish and implement a written respiratory protection program with worksite specific procedures for employees who wear N-95 respirators in the woodshop, exposing employees to hazards associated with inhalation of particles not otherwise regulated (PNOR), total fraction including saw dust/wood dust. (a) On or about March 22, 2018 and at times prior thereto the employer did not establish and implement a written respiratory protection program with worksite specific procedures for employees who wear half-faced respirators while painting pallets, exposing employees to hazards associated with inhaling A-100 Exterior Acrylic Latex Flat paint, including damage to organs.
Recent events (2)
- — I (S) $0
- — Z (S) $5691
1910.134 D01 III
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9135W103
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH: (a) On or about March 22, 2018 and at times prior thereto the employer did not identify and evaluate the respiratory hazards for employees exposed to particulates otherwise regulated (PNOR), total fraction and wood dust while cutting wood to make pallets in the woodshop; (b) On or about March 22, 2018 and at times prior thereto the employer did not identify and evaluate the respiratory hazards for employees using A-100 Exterior Acrylic Latex Flat paint while painting pallets.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9135W103
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about March 22, 2018 and at times prior thereto employees wearing N-95 respirators while cutting wood in the woodshop were not provided with a medical evaluation to determine their ability to use the respirator, exposing employees to hazards associated with using a respirator; (b) On or about March 22, 2018 and at times prior thereto employees wearing half-faced respirators while painting pallets were not provided with a medical evaluation to determine their ability to use the respirator, exposing employees to hazards associated with using a respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9135W103
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: (a) On or about March 22, 2018 and at times prior thereto employees wearing N-95 respirators while cutting wood in the woodshop were not provided with a fit test prior to initial use of the respirator, exposing employees to hazards associated with using a respirator; (b) On or about March 22, 2018 and at times prior thereto employees wearing half-faced respirators while painting pallets were not provided with a fit test prior to initial use of the respirator, exposing employees to hazards associated with using a respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) On or about March 22, 2018 and at times prior thereto half-faced respirators were worn by employees who had facial hair that came between the sealing surface of the respirator and the face, exposing employees to respiratory hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) On or about March 22, 2018 and at times prior thereto half-faced respirators were observed being stored in a driveway where they can be damaged by trucks and forklifts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9135W103
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (a) On or about March 22, 2018 and at times prior thereto employees wearing N-95 and half-faced respirators were not provided comprehensive, understandable annual training on the respirators, exposing employees to respiratory hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 A02
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $5,691 · Current $1,000 Reduced
9135W103
General-duty citation text
29 CFR 1910.1000(a)(2): Employees were exposed to airborne concentration of particulates not otherwise regulated, listed in Table Z-1, which is also referenced in Table Z-3 under Inert or Nuisance dust, in excess of 15 mg/m3 (total) as an 8-hour time weighted average. (a) The employer did not ensure that employee exposure to particulates not otherwise regulated (PNOR), total fraction, does not exceed 15 milligrams per cubic meter (mg/m3) of air as an 8-hour time weighted average (TWA). This violation occurred on or about March 22, 2018, at times prior thereto in the woodshop, where an employee working on the single head notcher was exposed to PNOR, total fraction, at an 8-hour TWA of 17.7 mg/m3 of air, approximately 1.18 times the PEL of 15 mg/m3. Sampling was performed for 425 minutes during one shift. Zero exposure was assumed for the 55 minute period not samples.
Recent events (2)
- — I (O) $1000
- — Z (S) $5691
1910.1000 E
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
9135W103
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d). (a) The employer did not determine and implement feasible administrative or engineering controls to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d). This violation was discovered on or about March 22, 2018, at times prior thereto the employer did not implement feasible administrative or engineering controls to achieve compliance with the prescribed exposure limit for particles not otherwise regulated, total fraction.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 B06
- Issued
- May 9, 2018
- Penalty
- Initial $1,423 · Current $592 Reduced
General-duty citation text
29 CFR 1904.32(b)(6): The OSHA 300-A Summary was not posted by February 1 of the year following the year covered by the records and/or kept in place until April 30: (a) On or about March 13, 2018 and at times prior thereto the employer did not post the OSHA 300-A Summary sheet for 2017
Recent events (2)
- — I (O) $592
- — Z (O) $1423
1904.32 B04
- Issued
- May 9, 2018
- Abate by
- Jun 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(b)(4): The company executive who certified the OSHA 300-A summary log was not an owner of the company, officer of the corporation, highest ranking company official, or the immediate supervisor of the highest ranking company official: (a) On or about March 13, 2018 the annual OSHA summary for the year 2017 was not certified by a company executive, but was certified by the Administrator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Pallet Place, LLC
View The Pallet Place, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343019634.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.