AMSTERDAM, OH —
OSHA Inspection: APEX ENVIRONMENTAL LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of APEX ENVIRONMENTAL LLC in 11 COUNTY ROAD 78, AMSTERDAM, OH 43903 (NAICS 562212). OSHA activity number 343073839.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APEX ENVIRONMENTAL LLC
- Site address
- 11 COUNTY ROAD 78
- City
- AMSTERDAM
- State
- OH
- ZIP
- 43903
- Mailing
- 11 COUNTY ROAD 78, AMSTERDAM, OH 43903
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562212
- Employees
- 110
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.132 D01 I
- Issued
- Jul 31, 2018
- Abate by
- Aug 31, 2018
- Penalty
- Initial $6,911 · Current $6,911
General-duty citation text
29 CFR 1910.132(d): Hazard assessment and equipment selection. 29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: 29 CFR 1910.132(d)(1)(i): Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; On or about April 9, 2018, the employer failed to select and require the use of personal protective equipment, including but not limited to leg protection for employees performing required duties that involved welding. Welders and welder's helpers job positions performed welding on a daily basis. Due to this condition, employees were exposed to thermal contact and increased risk for second and third degree burns.
Recent events (1)
- — Z (S) $6911
1910.132 D02
- Issued
- Jul 31, 2018
- Abate by
- Aug 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d): Hazard assessment and equipment selection. 29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. On or about April 9, 2018, the employer failed to perform and certify the performance of the personal protective equipment hazard assessment required by this part. Welders and welder's helpers job positions performed welding on a daily basis. Due to this condition, employees were exposed to thermal contact and increased risk for second and third degree burns.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Jul 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g): 600 Volts, nominal, or less. This paragraph applies to electric equipment operating at 600 volts, nominal, or less to ground. 29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. 29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded. On or about April 9, 2018, the working space about two electrical subpanel boxes and a "trough" style, horizontal feeder box located near the maintenance shop entrance door was not maintained free of stored items. A wheeled tool cabinet and vehicle light assembly were stored within the three feet working space required by Table S-1 from this part.
Recent events (1)
- — Z (O) $0
More inspections at Apex Environmental LLC
View Apex Environmental LLC's full OSHA safety record →
More inspections in this industry (NAICS 562212)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343073839.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.