Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PHOENIX MILLWORK, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PHOENIX MILLWORK, INC. in 1901 E. HOUSE ST., ALVIN, TX 77511 (NAICS 321918). OSHA activity number 343099693.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Phoenix Millwork, INC. — free Get an email when a new federal OSHA severe-injury report for Phoenix Millwork, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1901 E. HOUSE ST.
City
ALVIN
State
TX
ZIP
77511
Mailing
1901 E. HOUSE ST., ALVIN, TX 77511
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
80
Ownership type
A

9 citations on file for this inspection.

1910.134 E01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $3,880 · Current $0 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) At the facility, where the employees voluntarily wearing elastomeric half-face respirators had not received a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3880

1910.157 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 18, 2018
Penalty
Initial $3,298 · Current $1,979 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) In the manufacturing area, on April 19, 2018, where the mounted ABC portable fire extinguisher was blocked by a wood workstation that had a bench grinder resting on it.
Recent events (2)
  • — I (S) $1979
  • — Z (S) $3298

1910.178 P01

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    a) At the facility, on April 19, 2018, where a Starke forklift, model number FG 30, was in operation with a broken backup alarm and burned out lights.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.215 A04

Other-than-serious 1 instance 4 exposed
Issued
Sep 18, 2018
Penalty
Initial $4,398 · Current $0 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:    a) In the manufacturing area, on April 19, 2018, where a bench grinder was not equipped with a work rest.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4398

1910.303 G01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $6,467 · Current $3,880 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) In the shipping and receiving area, on April 19, 2018, where there was not sufficient space around the electrical panels, exposing employees to electrical hazards.    b) At the facility, near the rear employee break area, on April 19, 2018, where there was not sufficient space around the transformer step-up box and the electrical panel, which exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $3880
  • — Z (S) $6467

1910.305 A02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installations rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (A), (B) and (C) of this paragraph:  a) At the facility near the CNC machines, where flexible cords were used to supply electrical power to the building exhaust fans.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 4 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $726 · Current $435 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) At the facility, where employees were not provided with the information contained in Appendix D.
Recent events (2)
  • — I (O) $435
  • — Z (O) $726

1910.178 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $726 · Current $435 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    a) At the facility, where the forklift operators' performance was not evaluated at least once every three years.
Recent events (2)
  • — I (O) $435
  • — Z (O) $726

1910.1200 G08

Other-than-serious 1 instance 4 exposed
Issued
Sep 18, 2018
Abate by
Oct 22, 2018
Penalty
Initial $726 · Current $0 Reduced
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):    a) At the facility, where the employer did not ensure that the safety data sheets were readily accessible to the employees.  The employees work chemicals such as, but not limited to, lacquer thinner, surface bonder Xi, and formica 156 premium spray grade contact adhesive.
Recent events (2)
  • — I (O) $0
  • — Z (O) $726

View Phoenix Millwork, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343099693.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.