OSHA Inspection: NAN YA PLASTICS CORPORATION USA

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NAN YA PLASTICS CORPORATION USA in 2081 FM 102 ROAD, WHARTON, TX 77488 (NAICS 326113). OSHA activity number 343136784.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NAN YA Plastics Corporation USA — free Get an email when a new federal OSHA severe-injury report for NAN YA Plastics Corporation USA is published. One employer, no account, unsubscribe in one click.
Site address
2081 FM 102 ROAD
City
WHARTON
State
TX
ZIP
77488
Mailing
2081 FM 102 ROAD, WHARTON, TX 77488
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
Employees
400
Ownership type
A

4 citations on file for this inspection.

1910.95 I03

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 19, 2018
Abate by
Nov 15, 2018
Penalty
Initial $12,934 · Current $7,760 Reduced

Hazardous substances 8111

29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer:  At this establishment, employees engaged in manufacturing plastics were exposed to continuous and/or intermittent noise levels above the time-weighted average 85 decibel action level.  Employees were not provided with a variety of hearing protectors to ensure proper fitment and protection.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.132 D02

Serious Gravity 1 1 instance 250 exposed
Issued
Oct 19, 2018
Abate by
Nov 23, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  At this establishment, employees engaged in plastics manufacturing activities and were exposed to hazardous chemicals and noise.  The employer did not ensure a hazard assessment was conducted by means of a written certification.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.151 C

Serious Gravity 5 1 instance 30 exposed
Issued
Oct 19, 2018
Abate by
Nov 15, 2018
Penalty
Initial $7,391 · Current $4,435 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  At this establishment, employees engaged in plastics manufacturing activities were not provided with adequate eyewash stations where hazardous materials were handled and utilized, in that:  a.  no eyewash on the second floor of Department 1; b.  no eyewash on floors two, three, and four of Department 2; c.  no eyewash on floors two and three of Department 3; d.  eyewash in Department 2 did not have equal pressure for flushing; and, e.  eyewash outside of Department 1 did not have enough pressure to pop off dust covers.
Recent events (2)
  • — I (S) $4434.6
  • — Z (S) $7391

1910.305 G02 III

Other-than-serious 1 instance 6 exposed
Issued
Oct 19, 2018
Abate by
Nov 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  In Department 1, second floor, the flexible cord to an industrial pedestal fan was not connected with a functional strain relief device.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NAN YA Plastics Corporation USA's full OSHA safety record →