Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ILANI CASINO

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ILANI CASINO in 1 COWLITZ WAY, RIDGEFIELD, WA 98642 (NAICS 713210). OSHA activity number 343143012.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ilani Casino — free Get an email when a new federal OSHA severe-injury report for Ilani Casino is published. One employer, no account, unsubscribe in one click.
Establishment
ILANI CASINO
Site address
1 COWLITZ WAY
City
RIDGEFIELD
State
WA
ZIP
98642
Mailing
1 COWLITZ WAY, RIDGEFIELD, WA 98642
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
1100
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Other-than-serious 1 instance 3 exposed
Issued
Jun 27, 2018
Penalty
Initial $9,239 · Current $2,010 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    A)     In the shop, employees used a horizontal band saw that did not have the exposed parts of the blade guarded against accidental contact when the saw was in operation.
Recent events (2)
  • — I (O) $2009.75
  • — Z (S) $9239

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Jun 27, 2018
Abate by
Aug 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  A)     A fire extinguisher located in electrical room 2 had not received an annual inspection to make sure it was in proper operating condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343143012.