YIGO, GU —
OSHA Inspection: E.M.B. ELECTRICAL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E.M.B. ELECTRICAL INC. in P240 MWSS FACILITIES AT NORTH RAMP, AAFB, YIGO, GU 96929 (NAICS 238210). OSHA activity number 343151072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E.M.B. ELECTRICAL INC.
- Site address
- P240 MWSS FACILITIES AT NORTH RAMP, AAFB
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O.BOX 23665, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 24
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 D06 I
- Issued
- Jul 17, 2018
- Penalty
- Initial $3,142 · Current $2,199 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. On the east side of the maintenance facility: The snaphook for the fall protection lanyard was wrapped around and attached directly to the lanyard webbing. Employees engaged in electrical installation activities were exposed to fall hazards of approximately 18 feet.
Recent events (2)
- — I (S) $2199.4
- — Z (S) $3142
1926.502 D15
- Issued
- Jul 17, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. On the east side of the maintenance facility: The railing of the Haulotte Group Articulated Lift was used as an anchorage point for fall protection. Employees engaged in electrical installation activities were exposed to fall hazards of approximately 18 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at E.M.B. Electrical INC.