ABERDEEN, SD —
OSHA Inspection: NEW ANGUS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEW ANGUS, LLC in 13 135TH STREET SOUTH WEST P.O. BOX 190, ABERDEEN, SD 57401 (NAICS 311611). OSHA activity number 343171336.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW ANGUS, LLC
- Site address
- 13 135TH STREET SOUTH WEST P.O. BOX 190
- City
- ABERDEEN
- State
- SD
- ZIP
- 57401
- Mailing
- 13 135TH STREET SOUTH WEST P.O. BOX 190, ABERDEEN, SD 57401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311611
- Employees
- 800
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Jul 25, 2018
- Abate by
- Aug 20, 2018
- Penalty
- Initial $12,934 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a)New Angus, LLC dba DemKota Ranch Beef at 13 135th Street South West, Aberdeen, SD 57401: On or about and at times prior to May 14, 2018, the employer did not ensure that machine specific Lock-out/Tag-out procedures associated with multiple energy source machines were developed to protect employees from inadvertent machine start up. On May 14, 2018, a QA inspector received a left hand amputation injury involving the index, middle and ring finger after placing his hand on the side puller machine when the machine actuated during an inspection. The side puller machine was re-energized by a maintenance worker located in the basement of the facility prior to the completion of pre-op work inspections. When the side puller is hydraulically re-energized, the paddles of the machine automatically activated and cycled. The employer did not have specific procedures related to de-energizing the electrical functions related to the machine which would have disabled the paddles from cycling. This condition exposed employees to amputation injuries. Abatement Note: The procedures shall include but are not limited to the following: (1) A specific statement of the intended use of the procedures; (2) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (3) Specific procedural steps for the placement, removal and transfer of lockout devices or tag-out devices and the responsibility for them; and (4) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tag-out devices, and other energy control measures.
Recent events (2)
- — I (S) $8000
- — Z (S) $12934
More inspections at NEW Angus, LLC
View NEW Angus, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311611)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343171336.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.