MARIETTA, GA —
OSHA Inspection: TIP TOP POULTRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIP TOP POULTRY, INC. in 327 WALLACE ROAD, MARIETTA, GA 30065 (NAICS 311615). OSHA activity number 343232245.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIP TOP POULTRY, INC.
- Site address
- 327 WALLACE ROAD
- City
- MARIETTA
- State
- GA
- ZIP
- 30065
- Mailing
- 327 WALLACE ROAD, MARIETTA, GA 30065
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 750
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.28 B01 I
- Issued
- Dec 7, 2018
- Penalty
- Initial $10,163 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) Roofs Over Ice Machine Building and Engine Room #3; On or about June 12, 2018, and at times prior, the employer exposed employees to a 30 feet fall hazard, when employees jumped from one rooftop to another. b) Condenser Platforms; On or about June 12, 2018, and at times prior, the employer exposed employees to between 15 and 30 feet fall hazards when employees cleaned the condenser located on the roof of Engine Room #3
Recent events (2)
- — I (S) $9500
- — Z (S) $10163
1910.119 D03 I D
- Issued
- Dec 7, 2018
- Abate by
- Jan 28, 2019
- Penalty
- Initial $10,163 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(D): The employer did not include, in the process safety information compilation, the relief system design and the design basis. a) Ammonia Refrigeration System at Tip Top Poultry; On or about June 12, 2018, and at times prior, the employer exposed employees to asphyxiation hazards, in that the ammonia relief system design basis was not verified by appropriate calculations.
Recent events (2)
- — I (S) $0
- — Z (S) $10163
1910.119 D03 II
- Issued
- Dec 7, 2018
- Abate by
- Jul 29, 2019
- Penalty
- Initial $10,163 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) Ammonia Refrigeration System Machine Rooms #1 and #3; On or about June 12, 2018, and at times prior, the employer exposed employees to asphyxiation hazards, in that the ventilation systems were not designed to be automatically activated by an ammonia leak detection system as required by IIAR 2-1999.
Recent events (2)
- — I (S) $9500
- — Z (S) $10163
1910.119 J05
- Issued
- Dec 7, 2018
- Abate by
- Jul 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) in a safe and timely manner when necessary means where taken to assure safe operation. a) Ammonia Refrigeration System Machine Rooms #1 and #3; On or about June 12, 2018, and at times prior, the employer exposed employees to asphyxiation hazards, in that ammonia machine room detection system monitors were not operational or not present.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 E05
- Issued
- Dec 7, 2018
- Abate by
- Jul 28, 2019
- Penalty
- Initial $10,163 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not assure that PHA recommendations were resolved in a timely manner: a) Ammonia Refrigeration System at Tip Top Poultry; On or about June 12, 2018, and at times prior, the employer did not resolve recommendations from Process Hazard Analysis performed in 2013.
Recent events (2)
- — I (S) $0
- — Z (S) $10163
1910.119 J04 I
- Issued
- Dec 7, 2018
- Abate by
- Jul 29, 2019
- Penalty
- Initial $10,163 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment. a) On or about June 12, 2018 and at times prior, the employer did not perform tests on piping equipment that showed signs of deterioration from surface corrosion.
Recent events (2)
- — I (S) $9500
- — Z (S) $10163
1910.120 Q06
- Issued
- Dec 7, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $10,163 · Current $0 Reduced
General-duty citation text
29 CFR 1910.120(q)(6): Training was not based on the duties and function to be performed by each responder of an emergency response organization: a) Engine Rooms #1 and #3; On or about June 12, 2018, and at times prior, the employer did not ensure that first responders at the technician level received at least 24 hours of training.
Recent events (2)
- — I (S) $0
- — Z (S) $10163
1910.212 A01
- Issued
- Dec 7, 2018
- Penalty
- Initial $8,130 · Current $6,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Engine Room 1, Engine Room 3; On or about June 12, 2018, and at times prior, the employer exposed employees to amputation hazards in that rotating parts on the compressors were not guarded to prevent employees from having any part of the body in the danger zone during normal operations.
Recent events (2)
- — I (S) $6500
- — Z (S) $8130
1910.28 B11 II
- Issued
- Dec 7, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails in accordance with Table D-2, Stairway Handrail Requirements: a) Outside Engine Room 1; On or about June 12, 2018, and at times prior, the employer exposed employees to fall hazards, in that the 52" wide stair system having 11 risers leading to Engine Room 1 lacked stair rail protection on each open side.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.36 G01
- Issued
- Dec 7, 2018
- Abate by
- Jan 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(1): Ceiling of an exit route was not at least seven feet six inches. Any projection from the ceiling must not reach a point less than six feet eight inches from the floor. a) Engine Room 1; The employer exposed employees to entrapment hazards in that the exit route height was measured to be between approximately 6 feet 2 inches and 7 feet 4 inches from the floor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Dec 7, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Engine Room 1, Engine Room 3; On or about June 12, 2018, and at times prior, the employer exposed employees to fire hazards in that fans, lights, and compressors were plugged into flexible cords rather than a fixed wired outlet. b) Chemical Room; On or about June 12, 2018, and at times prior, the employer exposed employees to fire hazards in that sensors were plugged into an extension cord rather than a fixed wired outlet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 II
- Issued
- Dec 7, 2018
- Abate by
- Jan 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Engine Room 3; On or about June 12, 2018, and at times prior, the employer exposed employees to fire hazards in that the employer failed to remove a damaged cord from service on a light fixture.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TIP TOP Poultry, INC.
View TIP TOP Poultry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311615)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343232245.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.