OSHA Inspection: MCCREARY ROOFING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCCREARY ROOFING COMPANY in 501 EAST 38TH STREET, ERIE, PA 16546 (NAICS 238160). OSHA activity number 343260493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mccreary Roofing Company — free Get an email when a new federal OSHA severe-injury report for Mccreary Roofing Company is published. One employer, no account, unsubscribe in one click.
Site address
501 EAST 38TH STREET
City
ERIE
State
PA
ZIP
16546
Mailing
1404 EAST AVENUE, ERIE, PA 16503
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

9 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $5,174 · Current $5,000 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    A.)  McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees were using flexible electrical extension cords to power a DeWalt DC9310 Fast Charger to charge DeWalt DC9096 18V Battery Packs.  The flexible cord was not used in conjunction with a ground-fault circuit interrupter.  The company did not have an assured equipment grounding conductor program.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5174

1926.501 B10

Serious Gravity 10 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    A.)  McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees were preforming various roofing activities that included, but was not limited to, removing old roofing materials and installing new roofing.  A 35.5-foot section of roof was not protected by an acceptable method of fall protection.  Employees were exposed to a fall hazard of 23.8-feet.  Employees were not using a means or method of fall protection.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9054

1926.502 B15

Serious Gravity 10 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(15): Manila, plastic or synthetic rope being used for top rails or midrails were not inspected as frequently as necessary to ensure that it continues to meet the strength requirements of paragraph (b)(3) of this section:  A.)   McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:   Employees were preforming various roofing activities that included, but were not limited to, removing old roofing materials and installing new roofing.  The guard rail system was not inspected to ensure that the top rail and mid rail were taut.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $9,054 · Current $5,000 Reduced
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge:    A.)   McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, northeast comer of the roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees were preforming various roofing activities that included, but was not limited to, removing old roofing materials and installing new roofing.  The warning line system was 2.5-feet from the edge of the roof.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9054

1926.502 F02 IV

Serious Gravity 10 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(iv): The rope, wire or chain that acted as a warning line did not have a tensile strength of at least 500 pounds:  A.)   McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, northeast corner of the roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:   Employees were preforming various roofing activities that included, but was not limited to, removing old roofing materials and installing new roofing.  The warning line system was constructed of standard caution tape.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Other-than-serious 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  A.)  McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees utilize chemicals including, but not limited to, Blaster PB Penetrating Catalyst and Henry Pro-Grade Flashing Cement.  SDSs for the chemicals were not at the worksite.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 3 exposed
Issued
Nov 26, 2018
Abate by
Dec 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)  A.)   McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees utilize chemicals including, but not limited to, Blaster PB Penetrating Catalyst and Henry Pro-Grade Flashing Cement.  Employees did not have company-specific hazard communication training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.150 C01 VIII

Other-than-serious 1 instance 7 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  A.)  McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees were provided with, and permitted to use, a Badger multi-purpose dry chemical fire extinguisher (M/N:  10MB-8H, S/N:  BK-736630).  The fire extinguisher's last annual maintenance was in January 2017.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1053 B04

Other-than-serious 1 instance 2 exposed
Issued
Nov 26, 2018
Abate by
Dec 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  A.)  McCreary Roofing Company, 501 East 38th Street, Erie, PA 16546, roof area, east side of Weber Hall, on or about June 26, 2018 and times prior thereto:  Employees utilizing a Louisville FS2008 folding fiberglass ladder to access an upper roof.  The ladder was being used in the folded position.