Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTERN INTERNATIONAL GAS AND CYLINDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTERN INTERNATIONAL GAS AND CYLINDERS, INC. in 7173 HWY 159 EAST, BELLVILLE, TX 77418 (NAICS 325120). OSHA activity number 343318606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western International GAS and Cylinders, INC. — free Get an email when a new federal OSHA severe-injury report for Western International GAS and Cylinders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7173 HWY 159 EAST
City
BELLVILLE
State
TX
ZIP
77418
Mailing
7173 HWY 159 EAST, BELLVILLE, TX 77418
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325120
Employees
2500
Ownership type
A

4 citations on file for this inspection.

1910.29 B13

Other-than-serious 3 instances 4 exposed
Issued
Nov 26, 2018
Abate by
Jan 31, 2019
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.29(b)(13): When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening did not meet the requirements (b)(13)(i) or (b)(13)(ii) of this section.    On or about 19 July 2018, and at times prior thereto, platform ladderway openings were unguarded at the point of access to the platform, exposing employees to the hazard of falling in excess of more than 4 feet to the pavement below.  1) Southwest Generator Room: A fixed ladder allowed access to a platform approximately 11 feet 6 inches high in which the opening at the ladder was unguarded.  2) Northwest Generator Room: A fixed ladder allowed access to a platform approximately 11 feet 6 inches high in which the opening at the ladder was unguarded.  3) Silo: A fixed ladder allowed access to a platform approximately 13 feet 6 inches high in which the opening at the ladder was unguarded. An additional fixed ladder allowed access to a higher platform approximately 20 feet 6 inches high in which the opening at the ladder was unguarded.
Recent events (2)
  • — I (O) $4157.5
  • — Z (S) $8315

1910.119 E03 V

Deleted Serious Gravity 1 1 instance 170 exposed
Issued
Nov 26, 2018
Abate by
Dec 10, 2018
Penalty
Initial $4,989 · Current $0 Reduced
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address the hazards related to facility siting.  On or about 17 July 2018, and at times prior thereto, the process hazard analysis (PHA) for the Acetylene manufacturing and filling process did not include asbestos as a hazard for the purposes of addressing facility siting in the event of a fire and explosion, exposing employees within the plant to the hazards of asbestos-related health issues.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4989

1910.119 N

Other-than-serious 1 instance 170 exposed
Issued
Nov 26, 2018
Abate by
Jan 31, 2019
Penalty
Initial $8,315 · Current $4,158 Reduced
29 CFR 1910.119(n): The emergency action plan did not consider wind direction for the safeguarding of employees during an evacuation due to a release.      On 17 July 2017, and at times prior thereto, windsocks were not utilized by the employer as a means to protect employees during an emergency to indicate wind direction in the event of a vapor cloud release, exposing the employees to the hazard of an explosion or fire.
Recent events (2)
  • — I (O) $4157.5
  • — Z (S) $8315

1910.140 C13 I

Other-than-serious 1 instance 2 exposed
Issued
Nov 26, 2018
Abate by
Jan 31, 2019
Penalty
Initial $4,989 · Current $2,495 Reduced
29 CFR 1910.140(c)(13)(i): Anchorages were not capable of supporting at least 5000 pounds (22.2 kN) for each employee attached.    On or about 19 July 2018, and at times prior thereto, employees utilized process piping as an anchor point for fall protection, exposing the employees to a fall hazard of approximately 5 feet 6 inches to the concrete slab.
Recent events (2)
  • — I (O) $2494.5
  • — Z (S) $4989

View Western International GAS and Cylinders, INC.'s full OSHA safety record →