HENDERSON, TX —
OSHA Inspection: SUNDANCE CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUNDANCE CONSTRUCTION in 419 S. U.S. 79, HENDERSON, TX 75652 (NAICS 238130). OSHA activity number 343323176.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUNDANCE CONSTRUCTION
- Site address
- 419 S. U.S. 79
- City
- HENDERSON
- State
- TX
- ZIP
- 75652
- Mailing
- 613 CR 4586, WINNSBORO, TX 75494
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Aug 15, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. On or about July 6, 2018, employees working on a single story commercial building were exposed to head injury while working in areas where overhead work was in progress such as but not limited to framing activities.
Recent events (1)
- — Z (S) $3880
1926.403 B02
- Issued
- Aug 15, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification. The employer did not ensure that all equipment used was installed and used in accordance with instructions included in the listing, labeling, or certification. On or about July 6, 2018, employees, who were framing a single-story commercial building, were not protected from electrical shock when using an electrical power source that was installed per the listing, labeling, or certification of the manufacturer.
Recent events (1)
- — Z (S) $3880
1926.451 F15 II
- Issued
- Aug 15, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(f)(15)(ii): The employer did not ensure that platform units were secured to the scaffold to prevent their movement: On or about July 6, 2018, employees, who were framing a single-story commercial building, were not protected from approximately 12 feet to the concrete below when using a step ladder that was not secured to the scaffold platform.
Recent events (1)
- — Z (S) $3880
1926.501 B01
- Issued
- Aug 15, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about July 6, 2018, employees, who were framing a single-story commercial building, were not protected from approximately 12 feet to the concrete below.
Recent events (1)
- — Z (S) $3880
1926.1053 B04
- Issued
- Aug 15, 2018
- Abate by
- Aug 27, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.1053(b)(4): The employer did not ensure that ladders were used only for the purpose for which they were designed. On or about July 6, 2018, employees, who were framing a single-story commercial building, were exposed to a fall of approximately 12 feet to the concrete below.
Recent events (1)
- — Z (S) $3880
More inspections at Sundance Construction
View Sundance Construction's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343323176.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.