PLAINVIEW, TX —
OSHA Inspection: MARTIN MIDSTREAM PARTNERS L.P.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MARTIN MIDSTREAM PARTNERS L.P. in 1920 STATE HIGHWAY 194, PLAINVIEW, TX 79072 (NAICS 325312). OSHA activity number 343334421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARTIN MIDSTREAM PARTNERS L.P.
- Site address
- 1920 STATE HIGHWAY 194
- City
- PLAINVIEW
- State
- TX
- ZIP
- 79072
- Mailing
- P.O. BOX 191, KILGORE, TX 75662
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325312
- Employees
- 55
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.119 F03
- Issued
- Jan 9, 2019
- Abate by
- Jan 29, 2019
- Penalty
- Initial $5,543 · Current $5,543
General-duty citation text
29 CFR 1910.119(f)(3): The operating procedures were not reviewed as often as necessary to assure that they reflect current operating practice, including changes that result from changes in process chemicals, technology, and equipment, and changes to facilities. The employer did not annually certify that operating procedures were current and accurate. On or about July 24, 2018, at the Martin Midstream, L.P. facility located in Plainview, Texas, the employer did not annually certify operating procedures to ensure that they are current and accurate, this includes but is not limited to Ammonium Sulfate Operations, (6/29/12). The procedure was not annually certified from 2017 through 2018 and was found to be inaccurate.
Recent events (2)
- — I (O) $5543
- — Z (S) $5543
1910.119 G03
- Issued
- Jan 9, 2019
- Abate by
- Jan 29, 2019
- Penalty
- Initial $7,391 · Current $7,391
General-duty citation text
29 CFR 1910.119(g)(3): 1910.119(g)(3) Training documentation. The employer did not ascertain that each employee involved in operating a process has received and understood the training required by this paragraph. The employer did not prepare a record which contains the identity of the employee, the date of training, and the means used to verify that the employee understood the training. On or about July 24, 2018, the employer failed to ascertain that each employee involved in operating a process has received and understood the training required by this paragraph. This exposed employees to inhalation hazard at Martin Midstream located in Plainview, TX.
Recent events (2)
- — I (O) $7391
- — Z (S) $7391
1910.119 J02
- Issued
- Jan 9, 2019
- Abate by
- Jan 29, 2019
- Penalty
- Initial $12,934 · Current $7,760 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not implement written procedures to maintain the on-going integrity of process equipment On or about July 24, 2018, the employer failed to implement written procedures to maintain the on-going integrity of process equipment in accordance with employers Quarterly PSV Inspection Procedure PV-AA-PM-01, when it failed to replace pressure relief valves at five years interval, this exposed employees to inhalation hazard, at the Martin Midstream located in Plainview, Texas.
Recent events (2)
- — I (S) $7760.4
- — Z (S) $12934
1910.119 J04 I
- Issued
- Jan 9, 2019
- Abate by
- Jan 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment On or about July 24, 2018, the employer did not perform inspection and tests on process equipment in accordance with employers own Mechanical Integrity Policy, when it failed to replace pressure relief valves at interval that exceeded the five years designated, this exposed employees to inhalation hazard at Martin Midstream located in Plainview, TX. 1) PSV-30101 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 2) PSV-30102 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 3) PSV-30103 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 4) PSV-30104 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 5) PSV-30105 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 6) PSV-30106 PV-30101 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 3/17 7) PSV-30107 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 8) PSV-30108 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 9) PSV-30109 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 10) PSV-30110 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 11) PSV-30111 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 12) PSV-30112 PV-30102 Storage Bullet Rego AA3135UA250 1 1/4" 250 PSI exp. date 2/17 13) PSV-30135 P-30101 Liquid Pump for PV-30101 Rego SS8001G 1/4" 250 PSI exp. date 2/17 14) PSV-30134 P-30102 Liquid Pump for PV-30102 Rego SS8001G 1/4" 250 PSI exp. date 8/16 15) PSV-30140 PV-30103 Storage Bullet Rego A3149G 2 1/2" 250 PSI exp. date 8/17 16) PSV-30141 PV-30103 Storage Bullet Rego A3149G 2 1/2" 250 PSI exp. date 8/17 17) PSV-30142 PV-30103 Storage Bullet Rego A3149G 2 1/2" 250 PSI exp. date 8/17 18) PSV-30143 PV-30103 Storage Bullet Rego A3149G 2 1/2" 250 PSI exp. date 8/17 19) PSV-30166 3"-B2.1-AMM-30121 from Pumps P-30103 Rego SS8022G 1/2" 250 PSI exp. date 7/18 20) PSV-30130 NH3 Liquid Header Bottom Rego SS8022G 1/2" 250 exp. date 5/18 21) PSV-30131 NH3 Liquid Header Top Rego SS8022G 1/2" 250 PSI exp. date 5/18
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 O04
- Issued
- Jan 9, 2019
- Abate by
- Jan 29, 2019
- Penalty
- Initial $5,543 · Current $3,880 Reduced
General-duty citation text
29 CFR 1910.119(o)(4): The employer did not promptly determine and document an appropriate response to each of the findings of the compliance audit, and document that deficiencies have been corrected: On or about July 24, 2018, the employer failed to promptly determine and document an appropriate response to each of the findings of the compliance audit, and document that deficiencies have been corrected, this exposed employees to inhalation hazard at Martin Midstream located in Plainview, TX. This includes but is not limited to the following findings: a) Consider reviewing and updating the program documents or element procedures addressing all the elements of the PSM program, as necessary. b) Consider implementing the car seal program being developed on a corporate level to ensure that critical block valves are always maintained in the correct position (open or closed). c) Consider adopting the corporate deficiency management system or creating a temporary MOC whenever deficiencies in equipment are discovered to ensure that the deficiency situations are managed appropriately. d) Consider (1) closing the open action items from the 2008 and 2011 audits as soon as possible and (2) entering the corrective actions from the 2014 audit into the action tracker in the new ERM tool and tracking them to completion. e) Implement the draft task-based operating procedures with instructions for safely conducting the activities involved in each process area. f) Develop and implement a program to ensure that refresher training on operating procedures occurs at least every three years. The program should include consultation with employees on the frequency of refresher training and provide it more often if recommended.
Recent events (2)
- — I (S) $3880.1
- — Z (S) $5543
More inspections at Martin Midstream Partners L.P.
View Martin Midstream Partners L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 325312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343334421.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.