DEBARY, FL —
OSHA Inspection: SEMINOLE PRECAST MANUFACTURING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SEMINOLE PRECAST MANUFACTURING, INC. in 331 BENSON JUNCTION ROAD, DEBARY, FL 32713 (NAICS 238110). OSHA activity number 343341806.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEMINOLE PRECAST MANUFACTURING, INC.
- Site address
- 331 BENSON JUNCTION ROAD
- City
- DEBARY
- State
- FL
- ZIP
- 32713
- Mailing
- P.O. BOX 531059, DEBARY, FL 32753
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 73
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 24, 2018
- Penalty
- Initial $11,641 · Current $6,985 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. On or about July 26, 2018, the employer did not develop specific written procedures to lockout overhead cranes, a GEKA punch press, Rod Benders and KRB bending table, exposing employees to rotating parts and nip points when servicing equipment.
Recent events (2)
- — I (S) $6984.6
- — Z (S) $11641
1910.147 C05 II D
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s): a. On or about July 26,2018, a lockout devices placed on the Crane 50 was not identified as to who place the lockout device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about July 26, 2018, the employer did not conduct a periodic inspection of their lockout tagout program at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a. On or about July 26, 2018, the employer did not provide training to authorized and affected employees in the purpose and function of their lockout tagout program, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a lift: a. On or about July 26, 2018, the employer did not ensure that each forklift operator had completed the training prior to permitting an employee to operate a lift, exposing themselves to fall and crushing hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04
- Issued
- Oct 24, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4): 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every 3 years: a. On or about July 26, 2018, the employer did not conduct performance evaluations at least once every 3 years for all employees operating forklifts.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Seminole Precast Manufacturing, INC.
View Seminole Precast Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343341806.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.