OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genoa Lawn Center — free Get an email when a new federal OSHA severe-injury report for Genoa Lawn Center is published. One employer, no account, unsubscribe in one click.
Establishment
GENOA LAWN CENTER
Site address
5064 S. OLD 3C ROAD
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
5064 S. OLD 3C ROAD, WESTERVILLE, OH 43081
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811411
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2018
Abate by
Nov 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.  a. In the maintenance shop, there was no guard over the floor mounted pulley that was part of the hydraulic lift operating system.
Recent events (1)
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 9, 2018
Abate by
Nov 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.  a. In the maintenance shop, there was no guard over the floor mounted belt that was part of the hydraulic lift operating system.
Recent events (1)
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2018
Abate by
Nov 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees.   a. In the maintenance shop area, when it rained, the roof leaked water onto an electrical outlet, exposing employees to fire and electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2018
Abate by
Dec 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.  a. The employer did not develop a written hazard communication program when employees hazardous chemicals such as but not limited to, degreasers and cleaners.
Recent events (1)
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2018
Abate by
Dec 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.  a. The employer did not maintain safety data sheets for the chemicals, such as but not limited to, degreasers and cleaners, that were used in the maintenance shop area.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 9, 2018
Abate by
Dec 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.  a. The employer did not provide training to employees on the hazardous chemicals used in the maintenance shop, such as but not limited to, degreasers and cleaners.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343363008.