OSHA Inspection: FCA LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FCA LLC in 2348 FM 464, SEGUIN, TX 78155 (NAICS 321920). OSHA activity number 343441085.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FCA LLC — free Get an email when a new federal OSHA severe-injury report for FCA LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FCA LLC
Site address
2348 FM 464
City
SEGUIN
State
TX
ZIP
78155
Mailing
2348 FM 464, SEGUIN, TX 78155
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
47
Ownership type
A

5 citations on file for this inspection.

1910.147 D05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2018
Abate by
Sep 25, 2018
Penalty
Initial $12,934 · Current $7,760 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:    On or about August 27, 2018, at the dust collector, the employer failed to ensure potential energy was rendered safe. The employer did not have in place energy control procedures to stop the paddle wheel from turning from the weight of the sawdust in the hopper. Employees exposed to an amputation hazard from being struck by the unexpected turning of the paddle wheel blade from the gravitation force of the sawdust in the hopper.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.212 A01

Serious Gravity 10 3 instances 12 exposed
Issued
Sep 19, 2018
Abate by
Oct 24, 2018
Penalty
Initial $12,934 · Current $7,760 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about September 5, 2018, employees were utilizing Gantry Drills (#2, #3, #4) to make boxes and pallets without the rotating drill bits being guarded. Employees exposed to being struck-by the rotating drill bits.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.303 F02

Serious Gravity 1 1 instance 6 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about September 5, 2018, at the disconnect panel box labeled Gang Rip Saw, HC3, the breakers were not identified to indicate their purpose. Employees gain access to the disconnect box to isolate the energy sources for the Gang Rip Saw under the company's energy control program.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

1910.305 B02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about September 5 2018, near the lift table on Baldor 80 foot Gang Rip saw. The junction box near the table was missing the cover plate for the 110 volt wiring. Employees exposed to the hazard of an electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 2 instances 8 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $5,543 · Current $3,326 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:     On or about September 5, 2018, on the shop floor, there were two 110 volt pedestal fans that were not grounded. The fans were being operated and were missing the grounding pins. Employees exposed to the hazard of an electrical shock.
Recent events (2)
  • — I (S) $3325.8
  • — Z (S) $5543

View FCA LLC's full OSHA safety record →