Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PBX CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PBX CORPORATION in N. PEORIA AVE. BRIDGE OVER U.S. 75, TULSA, OK 74117 (NAICS 237310). OSHA activity number 343495529.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PBX Corporation — free Get an email when a new federal OSHA severe-injury report for PBX Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
PBX CORPORATION
Site address
N. PEORIA AVE. BRIDGE OVER U.S. 75
City
TULSA
State
OK
ZIP
74117
Mailing
P.O. BOX 644, SAPULPA, OK 74067
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
21
Ownership type
A

6 citations on file for this inspection.

1926.350 A09

Serious Gravity 5 4 instances 21 exposed
Issued
Oct 3, 2018
Penalty
Initial $2,765 · Current $1,659 Reduced
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position:    a.  On or about August 24, 2018, highway exit ramp hill side, a cylinder of compressed oxygen and a cylinder of acetylene were stored in a horizontal position on the ground and exposed employees to fire hazards.       b.  On or about August 24, 2018, highway exit ramp hill side, a cylinder of compressed oxygen and a cylinder of acetylene in a cart were in a horizontal position on the ground and exposed employees to fire hazards.
Recent events (2)
  • — I (S) $1659
  • — Z (S) $2765

1926.350 A10

Serious Gravity 5 1 instance 21 exposed
Issued
Oct 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    a.  On or about August 24, 2018, highway exit ramp hill side, a cylinder of compressed oxygen was stored next to a cylinder of acetylene and exposed employees to fire hazards
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.350 H

Serious Gravity 5 1 instance 21 exposed
Issued
Oct 3, 2018
Abate by
Oct 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.350(h): Oxygen, and fuel gas pressure regulators, or their related gauges were not in proper working order while in use:    a.  On or about August 24, 2018, highway exit ramp hill side, a regulator missing a cylinder gauge was installed on a compressed oxygen cylinder and exposes employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 2 instances 22 exposed
Issued
Oct 3, 2018
Penalty
Initial $691 · Current $415 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.    a.  On or about August 24, 2018, establishment, the employer did not provide the OSHA Form 300 for 2016 and 2018 within 4 business hours to an authorized government representative after a request was made.         b.  On or about August 24, 2018, establishment, the employer did not provide the OSHA Form 300A for 2016 within 4 business hours to an authorized government representative after a request was made.
Recent events (2)
  • — I (O) $414.6
  • — Z (O) $691

1926.1153 D02 II

Other-than-serious 1 instance 6 exposed
Issued
Oct 3, 2018
Abate by
Oct 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1153(d)(2)(ii): The employer did not assess the 8-hour TWA exposure for each employee on the basis of any combination of air monitoring data or objective data sufficient to accurately characterize employee exposures to respirable crystalline silica:    a.  On or about August 24, 2018, and at times prior, at the overpass bridge, the employer did not accurately assess employee exposure to crystalline silica during jack hammering of concrete when water was not applied at the point of impact or when a shroud and dust collection system was not used.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 2 instances 21 exposed
Issued
Oct 3, 2018
Abate by
Oct 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.    a.  On or about August 24, 2018, overpass bridge, the employer did not have a chemical inventory which included compressed oxygen and acetylene used by employees to cut metal and which exposes employees to hazardous chemicals.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PBX Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343495529.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.