Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UST SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UST SYSTEMS, INC. in 4611 EAST MARTIN LUTHER KING JR BLVD, AUSTIN, TX 78721 (NAICS 238910). OSHA activity number 343509410.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UST Systems, INC. — free Get an email when a new federal OSHA severe-injury report for UST Systems, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
UST SYSTEMS, INC.
Site address
4611 EAST MARTIN LUTHER KING JR BLVD
City
AUSTIN
State
TX
ZIP
78721
Mailing
4313 DELHI ST., HOUSTON, TX 77022
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 31, 2018
Abate by
Nov 15, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  On or about October 3, 2018, employees were not trained on the hazards associated with excavations, exposing the employees to the hazards of cave-ins and structural collapse.
Recent events (2)
  • — I (S) $3880
  • — Z (S) $3880

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 31, 2018
Abate by
Nov 2, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:  On or about October 3, 2018, employees working the in the excavation were not provided with a ladder every 25 feet, exposing the employees to the hazards of cave-ins.
Recent events (2)
  • — I (S) $3880
  • — Z (S) $3880

1926.651 K01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 31, 2018
Abate by
Nov 2, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.  An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift.  On or about October 3, 2018, the employer did not ensure that the competent person in charge on site conducted an inspection of the excavation before allowing employees to enter it, exposing the employees to the hazard of a cave-in.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 31, 2018
Abate by
Nov 2, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about October 3, 2018, the Werner 24 foot extension was set up in the excavation and was not extended 3 feet above the edge of the excavation, exposing employees to a hazards of approximately 15 feet.
Recent events (2)
  • — I (S) $2217
  • — Z (S) $2217

1926.652 A01

Willful Gravity 10 1 instance 2 exposed
Issued
Oct 31, 2018
Abate by
Nov 2, 2018
Penalty
Initial $25,867 · Current $25,867
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  On or about October 3, 2018, two employees were grading gravel in the bottom of an excavation up to approximately 14 feet and 8 inches deep without an adequate protective system in place, exposing the employees to the hazard of a cave-in.  The UST Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.652(a)(1), which was contained in OSHA inspection number 312926215, citation number 1, item number 4 and was affirmed as a final order on July 19, 2011, with respect to a workplace located at or around 1050 IH-10 South, Beaumont, TX 77707.
Recent events (2)
  • — I (W) $25867
  • — Z (W) $25867

View UST Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343509410.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.