OSHA Inspection: GENESIS HEALTHCARE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENESIS HEALTHCARE in 1751 N. 15TH STREET, ABILENE, TX 79603 (NAICS 623110). OSHA activity number 343570891.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genesis Healthcare — free Get an email when a new federal OSHA severe-injury report for Genesis Healthcare is published. One employer, no account, unsubscribe in one click.
Establishment
GENESIS HEALTHCARE
Site address
1751 N. 15TH STREET
City
ABILENE
State
TX
ZIP
79603
Mailing
1751 N. 15TH STREET, ABILENE, TX 79603
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
52
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Other-than-serious 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $7,577 · Current $4,546 Reduced
29 CFR 1910.22(a)(1):  All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:    a)  In the maintenance shop, equipment was strewn across the floor, exposing employees to slips/trips/fall hazards.
Recent events (2)
  • — I (O) $4546.2
  • — Z (S) $7577

1910.28 B13 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $11,366 · Current $6,820 Reduced
29 CFR 1910.28(b)(13)(i):  When work was performed less than 6 feet (1.6 m) from the roof edge, the employer did not ensure each employee was protected from falling by a guardrail system, safety net system, travel restraint system, or personal fall arrest system:    a) At the facility, where employees were not protected from falling by any type of a fall protection system when walking between their work area and the edge of the roof.
Recent events (2)
  • — I (S) $6819.6
  • — Z (S) $11366

1910.30 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $11,366 · Current $0 Reduced
29 CFR 1910.30(a)(1):  Before any employee was exposed to a fall hazard, the employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart:  a)  At the facility, employees performing HVAC work on the roof had not received training on the nature of the fall hazards in the work area and how to recognize them and the procedures to be followed to minimize those hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11366

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a)  At the facility, the west side door out of the laundry clean area was not clearly and visibly marked by a sign reading "Exit."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) In the maintenance shop, the portable fire extinguisher was not identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 2 exposed
Issued
Apr 25, 2019
Abate by
May 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):  Portable fire extinguishers were not subjected to an annual maintenance check:  a)  In the maintenance shop, the portable fire extinguisher was not inspected annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Genesis Healthcare's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343570891.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.